Electrical Requirements
For 21 kW Models:
30 Pound Electric Starting with Serial No. 9807017296
30 Pound Stacked Electric Starting with Serial No. 9807017398 (per pocket) not available in single phase.
Serial Plate
Voltage
208V/60Hz/1ph
240V/60Hz/1ph
200V/60Hz/1ph
200V/50Hz/1ph
230-240V/50Hz/1ph
200-208V/60Hz/3ph*
200V/50Hz/3ph*
230-240V/50Hz/3ph*
240V/60Hz/3ph*
380V/50Hz/3ph*
380V/50Hz/3ph
(0350SEL Model)
400-415V/50Hz/3ph*
460-480V/60Hz/3ph*
* These serial plate voltages are only options available on the 30 Pound Stacked Electric. Current (Amp) is for one pocket
only.
† Per heater on 30 Pound Stacked Electric unit. Unit has two heaters.
60
Terminal Block
Current
Connections
(Amps)
Required
L1, L2, Neutral,
107.7
and ground
L1, L2, Neutral,
and ground
L1, Neutral,
102.9
and ground
L1, Neutral,
104.6
and ground
L1, Neutral,
and ground
L1, L2, L3,
62.2†
and ground
L1, L2, L3,
and ground
L1, L2, L3,
54.9†
and ground
L1, L2, L3,
54.4†
and ground
L1, L2, L3,
33.4†
and ground
L1, L2, L3,
and ground
L1, L2, L3,
30.9†
and ground
L1, L2, L3,
and ground
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Recommended
Fuse or
Breaker Rating
(Amps)
150
94.2
125
150
150
95.0
125
80
60.4
80
70
70
50
33.5
50
40
26.9
35
Table 20
Recommended
Breaker
Minimum
Poles
Conductor Size
[AWG (mm
2
1/0 (63.62)
2
1 (50.27)
1
1/0 (63.62)
1
1/0 (63.62)
1
1 (50.27)
3
4 (24.62)
3
4 (24.62)
3
4 (24.62)
3
4 (24.62)
3
6 (14.19)
3
6 (14.19)
3
8 (8.81)
3
8 (8.81)
2
)]