Command And Safety Device Status Display Mode; Test Mode; Standby Mode - Roger Technology CTRL/P Instrucciones Y Advertencias Para El Instalador

Centrale di comando per barriere elettromeccaniche versione per parcheggi
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 141

• Command and safety device status display mode

COMMAND STATUS
AP
PED
PP
CH
ORO
POWER
C485
connected. The an indicator is flashing, the relative device has been disabled with a specific parameter.
Turning off the "BREAK" LED is always accompanied by the "STOP" LED turning off.

• TEST mode

The TEST mode is used to test activation of the commands and safety devices with visual confirmation.
To activate the mode, press the TEST button with the automatic barrier system at rest. If the barrier is moving, pressing TEST
stops the barrier. Pressing the button again enables TEST mode.
The flashing light and the barrier open indicator lamp illuminate for one second.
The command signal status is shown on the left hand side of the display for 5 seconds, ONLY when the respective command
signal is active (AP, CH, PP, PE, OR).
For example, if the open command is activated, the letters AP appear on the display.
The status of the safety devices/inputs is shown on the right hand side of the display. The number of the terminal relative to
the safety device in alarm state flashes.
Example: STOP contact in alarm state.
N.B.: If one or more contacts are open, the barrier will neither open nor close.
If more than one safety device is in alarm state, once the problem relative to the first device is resolved, the alarm for the next
device is displayed. Any further alarm states are also displayed with the same logic.
Press the TEST button again to exit test mode.
After 10 seconds with no user input, the display returns to command and safety device state display mode.

• Standby mode

POWER
62
SAFETY DEVICE STATUS
COMMAND STATUS:
The command status indicators on the display (segments AP = open,
FT
PP = step mode, CH = close, PED = partial opening, ORO=clock)
are normally off. They illuminate when a command is received (e.g.:
COS
BREAK
when a step mode command is received, the segment PP illuminates).
SAFETY DEVICE STATUS:
The safety device status indicators on the display (segments FT  =
photocells, COS = sensing edge, BREAK = BreakAway system ACS/
STOP/RELEASE
BA/60 magnetic sensor or STOP/RELEASE position) are normally on.
If an indicator is off, the relative device is in alarm state or is not
This mode is activated after 30 minutes with no user input. The POWER LED
flashes slowly.
Press UP
, DOWN
No safety device in alarm state or barrier waiting for
command.
STOP contact (N.C.) open.
Jumper the STOP contact.
Release handle or lock open.
Barrier inspection hatch open.
Sensing edge contact COS (N.C.) is open. Check
connection. If sensing edge is not installed, disable with
.
Photocell contact FT (N.C.) is open (message shown
on MASTER controller displayed). Check connection. If
photocell is not installed, disable with
Shatter-proof system enabled, or not connected or incor-
rectly connected (par.
)
, + or - to reactivate the control unit.
.