Enabling of management for opening with automatic re-closure exclusion.
If enabled, the exclusion of automatic re-closure only applies for the command selected via the parameter.
For example: if you set
following a PP or PED command.
NOTE: The command has open-stop-close or close-stop-open sequence activation function.
NOTE: The parameter is not visible if par.
Disabled.
An AP (open) command activates the opening manoeuvre. With the barrier fully open, automatic re-closure
is excluded. Another AP (open) command activates the closure manoeuvre.
A PP (step mode) command activates the opening manoeuvre. With the barrier fully open, automatic re-
closure is excluded. Another PP (step mode) command activates the closure manoeuvre.
A PED (partial opening) command activates the partial opening manoeuvre. Automatic re-closure is exclu-
ded. Another PED (partial opening) command activates the closure manoeuvre.
Electric lock type selection
Disabled.
Normally not powered. The electric lock is powered at the start of the opening manoeuvre to allow the
barrier to open.
Normally powered. Power to the electric lock is disconnected at the start of the opening manoeuvre to
allow the barrier to open.
Obstacle detection function setting (crush prevention)
The barrier reopens if the obstacle detection system is activated during a closing manoeuvre.
During opening manoeuvres, the barrier is reversed by the obstacle detection system only if the obstacle
is detected within the first 60° of the manoeuvre.
The maximum number of automatic closing attempts is set by parameter
01= minimum activation time (maximum sensitivity)... 09= maximum activation time (minimum sensitivity).
The barrier remains stationary against the obstacle for a maximum time of 5 s before reversing.
Setting opening speed
N.B.: Ambient conditions and the spring setting may cause manoeuvre times to vary.
Setting closure speed
N.B.: Ambient conditions and the spring setting may cause manoeuvre times to vary.
01= minimum speed (manoeuvre time = 3,5 s)... 10= maximum speed (manouvre time = 1,2 s).
Number of automatic closure attempts after activation of sensing edge or
obstacle detection (crush protection)
No automatic closure attempts.
From 1 to 3 automatic closure attempts.
Automatic closure is only performed if the barrier is completely open.
We recommend setting a value equal to or lower than the value set for parameter
Photocell mode for barrier opening (FT)
N.B.: this parameter is not visible if the value of parameter
DISABLED. Photocell is not active or not installed.
STOP. The barrier stops and remains stationary until the next command is received.
IMMEDIATE REVERSE. The barrier reverses immediately if the photocell is activated during opening manoeuvre.
TEMPORARY STOP. The barrier stops and remains stationary as long as the photocell is obstructed. The
barrier resumes opening when the photocell is cleared.
DELAYED REVERSE. The barrier stops if the photocell is obstructed. The barrier closes when the photocell
is cleared.
Photocell mode for barrier closure (FT)
N.B.: this parameter is not visible if the value of parameter
DISABLED. Photocell is not active or not installed.
STOP. The barrier stops and remains stationary until the next command is received.
, automatic re-closure is excluded following an AP command, but it is activated
or
is different than
.
.
=
,
or
.
=
,
or
.
69