Operating mode of signal lights on boom
N.B.: to reduce power consumption, the controller automatically sets this parameter to
powered operation.
Disabled. Lights always off.
Lights always on.
Lights on with boom stationary, flashing when boom is moving.
Short flash with boom stationary, flashing normally when boom is moving.
Short flash with boom closed, flashing normally when boom is moving, off when boom is open.
Clock contact configuration.
When the clock function is active, the barrier opens and remains open.
When the programmed time has elapsed, the barrier closes.
When the clock function is active, the barrier opens and remains open. Any command signal received is ignored.
When the clock function is active, the barrier opens and remains open. Any command signal received is
accepted. When the barrier returns to the completely open position, the clock function is reactivated.
Enable safeguarded barrier closure/opening
Enabling this parameter ensures that the barrier is not left open due to incorrect and/or accidental com-
mands or due to strong gusts of wind.
This function is NOT enabled if:
• the barrier receives a STOP command;
• the sensing edge is activated;
• the number of closure attempts set by parameter
Disabled. Parameter
is not visible.
Enabled. After a period of time set with parameter
warning with the flashing light, regardless of the parameter
Enabled.
If the barrier is closed as a result of a step mode command, after a period of time set with parameter
the control unit signals a 5 second warning with the flashing light (regardless of the parameter
then the barrier closes.
If the barrier is stopped by the obstacle detection system during a closure manoeuvre, the barrier closes
after a period of time set with parameter
If the barrier is stopped by the obstacle detection system during an opening manoeuvre, the barrier open
after a period of time set with parameter
Safeguarded closure/opening activation time setting
N.B.: This parameter is not visible if
Wait time settable from 2 to 90 s.
Wait time settable from 2 to 9 min.
Parking access mode selection
N.B.: If enabled with values
trigger a reopening manoeuvre unless parameter
are not visible.
For more information, see chapter 14 "Examples of applications in parking access mode".
Disabled. Parameter
is not visible.
Bi-directional mode ith immediate clo ure.
When entering and leaving the parking area, the barrier is opened with an AP open command.
Once the vehicle has crossed the barrier and released contact FT (NC) (e.g. from magnetic loop), the barrier
closes immediately.
When parameter
=
, the barrier open and remains open until the vehicle has completed the passage.
If the vehicle moves back, the barrier remains open.
NOTE: it is possible to add further 5 s delay before closing, setting
Directional mode 1. When entering the parking area, the barrier is opened with an AP open command.
Once the vehicle has crossed the barrier and released contacts FT (NC) and PED (NO), the barrier closes.
When leaving the parking area, the barrier is opened by a PED command received from the magnetic loop.
Once the vehicle has crossed the barrier and released contact FT (NC), the barrier closes.
When parameter
=
, the barrier open and remains open until the vehicle has completed the passage.
If the vehicle moves back, the barrier remains open.
NOTE: it is possible to add further 5 s delay before closing, setting
has been reached.
, the control unit signals a 5 second pre-manoeuvre
.
.
=
.
,
or
, photocell activation during a closing manoeuvre will always
is set. Parameters
and then closes the barrier.
,
,
,
.
.
during battery
,
), and
,
and
71