17
Procedural verifications - INFO Mode
TEST
x5 s
INFO mode may be used to view certain parameters measured by the CTRL/P controller.
Press and hold the TEST button for 5 seconds from the "View command signals and safety devices" mode with the motor
stationary. The controller displays the following parameters in sequence:
Parameter
Function
.
View only for 3 s the firmware version of the control unit.
View the duration of the manoeuvre (opening or closing) in second (example:
View barrier position (ENCODER data) at time of test, in motor revolutions.
(example:
View total length of programmed travel, in motor revolutions (e.g.:
View motor speed, in revolutions per minute (rPM).
View current absorption of motor, in Amperes (e.g.:
If the motor is stationary, the current absorption value is 0.
System OK indicator. To check for overloading (e.g.: too many utilities connected to 24 V output) or if the
mains voltage is too low, compare the parameters read with values indicated as follows with the motor
stationary:
mains voltage = 230 V AC (nominal), bUS=
mains voltage = 207 V AC (-10%), bUS=
mains voltage = 253 V AC (+10%), bUS=
Indicates time taken by motor to detect an obstacle, as set with parameter
E.g. .
Indicates the state of the automation system (open/closed).
automation system opening (motor active).
automation system closing (motor active).
automation system completely open (motor not actives).
automation system completely closed (motor not actives).
Indicates activation of the obstacle detection system.
obstacle detection activated.
mains voltage too low or overload.
motors overcurrent.
• Use the + / - buttons to scroll through the parameters. When the last parameter in the sequence is reached, press the -
button to return through the previous parameters.
• In INFO mode, the automation system may be activated to test operation in real time.
• Press and hold the TEST button for a few seconds to exit INFO mode.
78
. = barrier installed on the right;
= 1 s / .
= 0.12 s (120 ms). Ensure that the manoeuvre time is more than 0.3 s.
...
. = barrier installed on the left).
. = 37.8 motor revolutions).
. = 16.5 A).
.
.
.
TEST
TO QUIT THE
INFO MODE
1 click
. = 1.2 ses).
, in seconds.