PROBLEMS
Some problems which may arise while using the lift are listed here below. Ravaglioli declines all responsibility for damages to people, animals and
objects caused by unauthorized staff. Moreover, if faults occur you are advised to contact the technical service assistance to receive advice and
information on how to carry out work and/or adjustments in maximum safety conditions, thus avoiding the risk of causing damages to people,
animals and objects.
Technical service is required. Intervention by others prohibited.
PROBLEM
Machine not working
Machine carries out rise
movement but not descent
Descent is carried out at
extremely slow speed
The motor is working
properly but lifting cannot
be carried out
The motor is working
properly but the rise speed
is extremely slow
The rated capacity
cannot be raised
Platforms not
syncronised
Release cylinders not
working
Tab. 7
RAV 709 - RAV 709 I
RAV 713 - RAV 713 I
CAUSE
a) Main switch to "0"
b) Transformer fuse or general
protective fuses interrupted
c) Electrical system faulty
d) Rise limit switch with contacts open
(blocked, broken or not
connected).
e) Thermal motor probe activated.
a) Descent solenoid valve blocked in
closed position
a) The flow regulating valve is not
working properly
a) Descent solenoid valve blocked in
open position.
b) Pump suction filter blocked.
c) Drive joint broken
d) Calibrating valve not
working properly
a) The descent solenoid valve is
partially open.
b) Pump suction filter partially
blocked
c) Pump used or damaged
d) Calibrating valve not
working properly
a) Calibrating valve not
working properly.
b) Pump used or damaged.
a) Alignment valve faulty.
b) Worn seals in hydraulic cylinders.
a) Release solenoid valve not working
properly.
b) Release cylinder seal damaged or
used.
c) Pneumatic hoses damaged or
throttled
SOLUTION
a) Turn to "I".
b) Replace used fuses
If a fuse interrupts again, find the
cause of the problem
c) Check efficiency, components
and connections (push buttons,
solenoid starter, thermal probe,
transformer).
d) Reset the limit switch and replace if
necessary.
e) Wait for reset
a) See "maintenance" chapter
a) See "Maintenance" chapter
a) See "Maintenance" chapter.
b) Clean filter
c) Replace joint
d) Ask for technical
assistance
a) See "Maintenance" chapter.
b) Clean filter.
c) Replace pump.
d) Ask for technical
assistance
a) Ask for dealer assistance.
b) Check pump efficiency and replace if
necessary.
a) Check that tap R (fig. 31) is closed.
Clean valve if necessary and bleed air.
b) Replace seals.
a) See "Maintenance" chapter.
b) Replace seal.
c) Check hoses.