Manually Terminating Calibration / Reconditioning
At any time during IMPRES or IMPRES 2 battery discharge (Steady
Amber), Calibration / Reconditioning may be terminated. Perform the
following steps:
1. Remove the battery from the charger pocket.
2. Within 5 seconds, reinsert the battery into the charger pocket.
Battery discharge immediately terminates, and Normal battery
charging starts. The LED indicates Charge Status.
End-of-Service-Life Indication
As batteries are used, normal wear reduces available capacity.
At the successful completion of Calibration / Reconditioning, IMPRES
chargers compare IMPRES battery capacity to the battery Rated
Capacity. When the capacity is at a very low value, the IMPRES battery
may be nearing its End of Service. The IMPRES battery remains
usable. In some scenarios, it may be desirable to deploy the battery to
someone who does not require large battery capacity to complete a
work shift.
Radio or Battery Charging Procedure
Batteries charge best at room temperature. Batteries may be attached
to a radio or stand-alone.
1. Place the Multi-Unit charger on a flat surface.
2. Firmly insert the power supply into the charger DC Inlet Socket at
the back of the charger.
3. Plug the power supply power cord into a matching power outlet.
4. On the IMPRES 2 Adaptive Multi-Unit Charger System, each
pocket Status LED will flash Green for one second and
"IMPRES 2 CHARGER" will be displayed upon successful
power-up. If the Status LED's do not flash, and no message is
displayed, check power cord connections.
5. Insert the radio with battery or stand-alone battery into an available
pocket.
11