Parflange 1050
Trouble Shooting - Feeder
Fault
The sleeve is still in the
tool
Feeder jaw is not in
reception position
Feeder jaw is not up
Feeder jaw is not down
Clamping cylinder is not
closed
Clamping cylinder is not
open
Source
The feeder jaw cannot
insert anew because the
sensor is activated.
Sensor for the reception
position is not activated.
• Feeder jaw / sensor
not in correct
position
• Sensor / connection
line defective
Sensor for inquiry position
"feeder jaw upward" is not
activated.
• Feeder jaw / sensor
not in correct
position
• Sensor / connection
line defective
Sensor for inquiry position
"feeder jaw downward" is
not activated.
• Feeder jaw / sensor
not in correct
position
• Sensor / connection
line defective
Pressure switch for clamp
is not activated
Pressure switch for clamp
is activated
54
Clearance
Activate emergency-OFF
and remove the sleeve.
If no sleeve can be found,
check the sensor/clean it.
Acknowledge the
disturbance after its cause
has been cleared.
Activate emergency-OFF,
check position of the
feeder jaw, check / clean
sensor –10B5.
Acknowledge the
disturbance after its cause
has been cleared.
Activate emergency-OFF,
check position of the
feeder jaw, check / clean
sensor –10B3.
Acknowledge the
disturbance after its cause
has been cleared.
Activate emergency-OFF,
check position of the
feeder jaw, check / clean
sensor –10B4.
Acknowledge the
disturbance after its cause
has been cleared.
Activate emergency-OFF,
check the condition and
functions of the clamp,
check / clean pressure
switch –10B7.
Acknowledge the
disturbance after its cause
has been cleared.
Activate emergency-OFF,
check the condition and
functions of the clamp,
check / clean pressure
switch.
Acknowledge the
disturbance after its cause
has been cleared.