Siemens POINTEK CLS200 Manual De Arranque Rápido página 13

Ocultar thumbs Ver también para POINTEK CLS200:
Tabla de contenido

Publicidad

Level Measurement
Point level measurement
RF Capacitance switches
Pointek CLS300 - Digital
Selection and Ordering data
Pointek CLS300 - Digital - High Temperature
Rod version with Threaded or Flanged process
connection
Inverse frequency shift capacitance level and
material detection switch with optional rod/cable
choices and configurable output. It is ideal for
detecting liquids, solids, slurries, foam, and inter-
faces in demanding conditions where high pres-
sure and temperatures are present and has the
ability to tune out buildup on the probe.
Click on the Article No. for the online configura-
tion in the PIA Life Cycle Portal.
Process connection
Threaded, 316L stainless steel
¾" NPT [(Taper), ANSI/ASME B1.20.1]
1" NPT [(Taper), ANSI/ASME B1.20.1]
1¼" NPT [(Taper), ANSI/ASME B1.20.1]
1½" NPT [(Taper), ANSI/ASME B1.20.1]
4
R ¾" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203]
R 1" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203]
R 1½" [(BSPT), EN 10226/PT (JIS-T),
JIS B 0203]
G ¾" [(BSPP), EN ISO 228-1/PF (JIS-P),
JIS B 0202]
G 1" [(BSPP), EN ISO 228-1/PF (JIS-P),
JIS B 0202]
G 1½" [(BSPP), EN ISO 228-1/PF (JIS-P),
JIS B 0202]
Welded flange, 316L stainless steel, raised face
1" ASME, 150 lb
1" ASME, 300 lb
1" ASME, 600 lb
1½" ASME, 150 lb
1½" ASME, 300 lb
1½" ASME, 600 lb
2" ASME, 150 lb
2" ASME, 300 lb
2" ASME, 600 lb
3" ASME, 150 lb
3" ASME, 300 lb
3" ASME, 600 lb
4" ASME, 150 lb
4" ASME, 300 lb
4" ASME, 600 lb
Welded flange, 316L stainless steel,
Type A flat faced
DN 25, PN 16
DN 25, PN 40
DN 40, PN 16
DN 40, PN 40
DN 50, PN 16
DN 50, PN 40
DN 80, PN 16
DN 80, PN 40
DN 100, PN 16
DN 100, PN 40
(Note: Flange bolting patterns and facings
dimensionally correspond to the applicable
ASME B16.5 or EN 1092-1 standard.)
Probe length
(length from flange face)
(threaded lengths include process thread)
Note: No Y01 needed in Order code for
standard lengths
Standard version rod, 350 mm (13.78 inch)
Extended rod, length 500 mm (19.69 inch)
Extended rod, length 750 mm (29.53 inch)
Extended rod, length 1 000 mm (39.37 inch)
4/52
Siemens FI 01 · 2018
© Siemens AG 2018
Article No.
Selection and Ordering data
7ML5662-
Pointek CLS300 - Digital - High Temperature
Rod version with Threaded or Flanged process
0
-
7 7 7
7
7 7 7 7
connection
Inverse frequency shift capacitance level and
material detection switch with optional rod/cable
choices and configurable output. It is ideal for
detecting liquids, solids, slurries, foam, and inter-
faces in demanding conditions where high pres-
sure and temperatures are present and has the
ability to tune out buildup on the probe.
Add Order code Y01 and plain text:
"Insertion length ... mm"
Extended rod, factory adjusted length
250 ... 499 mm (9.8 ... 19.65 inch)
Extended rod, factory adjusted length
0 A
500 ... 749 mm (19.69 ... 29.49 inch)
0 B
Extended rod, factory adjusted length
0 C
750 ... 999 mm (29.53 ... 39.3 inch)
0 D
Wetted seals
1 A
Graphite
1 B
Probe material
1 D
316L stainless steel with ceramic (ZrO
3 A
Approvals
Dust Ignition Proof:
3 B
CE, RCM, ATEX II 1/2 D, 2 D IP6X T100 °C
Intrinsically Safe
3 D
CE, RCM, ATEX II 1 G EEx ia IIC T6 ... T4,
ATEX II 1/2 D, 2 D IP6X T100 °C
Flameproof Enclosure with IS Probe:
CE, RCM, ATEX II 1/2 G EEx d[ia] IIC T6 ... T4,
5 A
ATEX II 1/2 D T100 °C
5 B
Intrinsically Safe
5 C
CSA/FM Class I, Div. 1, Groups A, B, C, D
CSA/FM Class II, Div. 1, Groups E, F, G
5 D
CSA/FM Class III T4
5 E
Explosion Proof Enclosure with IS Probe:
5 F
CSA/FM Class I, Div. 1, Groups A, B, C, D
5 G
CSA/FM Class II, Div. 1, Groups E, F, G
CSA/FM Class III T4
5 H
5 J
General Purpose (CSA, FM)
5 K
General Purpose (CSA, FM, CE, RCM)
5 L
Enclosure and Lid
5 M
Aluminum epoxy coated
5 N
2 x ½" NPT via adapter - cable inlet, IP65
5 P
2 x M20 x 1.5 cable inlet, IP65
5 Q
2 x ½" NPT via adapter - cable inlet, IP68
2 x M20 x 1.5 cable inlet, IP68
Active shield length
6 A
Standard length -
6 B
(125 mm threaded, 105 mm flanged)
6 C
Extended shield -
(250 mm threaded, 230 mm flanged)
6 D
Extended shield -
6 E
(400 mm threaded, 380 mm flanged)
6 F
1)
Barrier or Intrinsically Safe power supply required for Intrinsically Safe
6 G
protection
6 H
2)
Available with Probe version options B ... D, F, G only
6 J
[t 500 mm (19.69 inch)]
6 K
3)
Available with Probe version options C, D, and G only
[t 750 mm
A
B
C
D
) isolators
2
1)
1)
2)
3)
(29.53 inch)]
Article No.
7ML5662-
0
-
7 7 7
7
7 7 7 7
E
F
G
0
0
B
C
D
F
G
H
J
A
B
C
D
0
1
2

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Pointek cls300

Tabla de contenido