Figure 97. Removing the status LED control panel for Rear Accessed configuration
Next steps
Replace the status LED control panel for Rear Accessed
Installing the status LED control panel for Rear Accessed
configuration
Prerequisites
1. Follow the safety guidelines listed in the
2. Follow the procedure listed in the
3.
Remove the air
shrouds.
4.
Remove the processor and heat sink module.
5.
Remove the expansion card riser
NOTE:
If necessary, please remove the backplane signal and power cables.
Steps
1. Align and insert the status LED control panel assembly in the slot on the system.
2. Route the status LED control panel cable through the guide slots in the system and connector on system board.
NOTE:
Route the cable properly to prevent the cable from being pinched or crimped.
3. Using the Torx 8 screwdriver, tighten the screws that secure the left control panel assembly to the system.
NOTE:
Los números de la imagen no muestran los pasos exactos. Los números son solo para la representación de la
secuencia.