WARNING: When inspection and operational testing reveals defects in or
damage to equipment, inadequate maintenance of equipment, or evidence of
equipment having been exposed to fall arrest forces or loading, the equipment
shall be immediately removed from service and submitted to a new inspection
by competent person or authorized repair center.
INSPECTION REQUIREMENTS
The periodic inspections must be conducted by a competent person (other than
the user) according to the following schedule. (*See note in 7.2 Maintenance).
Type of
Use
Infrequent
to Light
space, Factory
maintenance
Moderate
Transportation,
to
Heavy
construction,
Severe to
Continuous
construction,
* Competent person: person, designated by employer, who has a safety expertise
and a technical background on such SRL (specific training)
7-2 MAINTENANCE
Basic care of all fall protection equipment will prolong its service life and will
contribute toward the performance of its vital safety function.
SERVICING
With the exception of the field replaceable lifeline made by a competent person,
servicing of self-retracting lifelines must only be carried out by Honeywell Safety
Products or persons or entities authorized in writing by Honeywell. A record log
of all servicing and inspection dates for this device must be maintained (see
appendix – inspection sheet). Complete the inspection grid label with the next
due date (year/month), according required frequency but not more than 1 year.
Only original replacement parts are approved for use in this device. Contact your
Honeywell distributor or call Honeywell Technical Service
is.ppe.techsupport.europe@honeywell.com, for any return.
CLEANING AND STORAGE
Periodically clean the exterior of the device and wipe the lifeline using a damp
cloth and mild detergent.
When not in use, equipment shall be stored in a manner as to preclude damage
from environmental factors, such as temperature, light, UV, excessive moisture,
22
Application
Examples
Rescue &
confined
temperature, clean environments
Residential
Utilities,
Warehouse
Commercial
prolonged or continuous outdoor
Oil & Gas,
Mining
Conditions of Use
Good storage conditions, indoor
or infrequent outdoor use, room
Fair storage conditions, indoor
and extended outdoor use, all
temperatures, clean or dusty
environments
Harsh storage conditions,
use, all temperatures, dirty
environment
Inspection
Frequency
Competent
Person*
Annually
Semi-
annually to
annually
Quarterly
to semi-
annually
00 800 33 44 28 03
/