SATA ROB Automatic Gun Operating Instructions
EN
Adjust spray fan pattern
■ Use the control to adjust the flat fan by means of the flat fan air pres-
sure.
■ Use the control to adjust the round fan by means of the round fan air
pressure.
Painting
Notice!
When painting, only use as much material as is required for the specific
procedure.
When painting, maintain the necessary spray distance (see chapter 4).
After painting, store or dispose of the material correctly.
■ Adjust the necessary spray distance (see chapter 4).
■ Ensure there is sufficient spraying air feed and material supply.
■ Use the control air to trigger the control pulse for painting.
Switch off the automatic gun
■ Switch off the control air.
■ If the spraying process has finished or a lengthy spraying break is
planned, switch off flat and round fan air after the material supply and
note and follow the care and storage instructions (see chapter 11).

10. Maintenance and repairs

The following chapter describes the procedures involved for maintaining
and repairing the automatic gun.
If maintenance work is performed while the gun is still connected to the
compressed air circuit and material supply, components can unexpect-
edly work loose and material can leak.
→ Empty the automatic gun before all kinds of maintenance work and
then disconnect it from the compressed air circuit and the material sup-
ply.