UK
• If there are several devices with N.C. contacts for the same control unit input, they should be connected in
series.
• Do not make modifications unless provided for in these instructions. The manufacturer declines all
responsibility for improper functioning of the automated device if the original components and
accessories suitable for the specific application are not used.
• The construction of automatic doors, gates and garage doors is subject to the following regulations:
EN 12453 Industrial and commercial doors, gates and garage doors.
Safety in use of motorized doors - Requirements
EN 12978 Industrial and commercial doors, gates and garage doors. Safety devices for motorized doors
and gates - Requirements and test methods.
• This instruction manual addresses persons qualified for installation of "live equipment". Therefore, good
technical knowledge and professional practice in compliance with the regulations in force are required.
• Maintenance must be carried out by qualified personnel.
• Before carrying out any cleaning or maintenance operation, disconnect the control unit from the mains.
• Use of the product for purposes different from the intended use has not been tested by the manufacturer,
therefore any work is carried out on full responsibility of the installer.
ELECTRICAL CONNECTIONS: TERMINAL BOARDS
Terminal
Position
1
2
3
4
5
6
M1
7
8
9
10
11
12
N.B.. terminal no. 7 is connected to a ground, therefore, in case of direct current pay attention to the
polarity.

WARNINGS FOR THE USER

In the event of an operating fault or failure, cut the power upstream of the control unit and call Technical
Service.
Any repairs must be carried out by specialised personnel using original and certified materials.
Signal
Description
S11
Input for 8.2KΩ sensing device
S21
Input for 8.2KΩ sensing device
S12
Output TEST with N.O. clean contacts
S22
Output TEST with N.O. clean contacts
RES
Reset connection
RES
Reset connection
A2
Power supply -24Vdc / 24Vac
A1
Power supply +24Vdc / 24Vac
CONT2B
Output with NC contact 2
CONT1B
Common output 1
1CONT1A
Output with NC contact 1
CONT2B
Common output 2
DSC
BOARD RESET
Closed contact with frame operated
and board powered