Recall from the User Memory - recall the
stored programs from the user Memory. To
recall the Welding Program from the User
Memory:
Note: Before using, the Welding Program had to be
assigned to the user memory
Add the "Load" icon to the Welding Parameters Bar.
Use the right knob [44] to highlight the "Load" memory
icon.
Press the right knob [44] to confirm – the "Load"
memory menu is shown on the display.
Use the right knob [44] to highlight the Memory
number from which Welding Program will be recall.
Confirm the selection – press the right button [44].
Save to the User Memory - Store the
welding programs with their parameters to
one of the fifty user memories. To save in
memory:
Add icon „Save to the User Memory" to Welding
Parameters Bar.
Use the right knob [44] to highlight the icon „Save to
the User Memory".
Figure 23
Press the right knob [44] to confirm - „Save to the User
Memory" is shown on the display.
Use the right knob to highlight the memory number
where the program would be stored.
Figure 24
English
Confirm selection – press and hold for 3 second right
knob [44].
Rename job – turn right knob [44] to select: numbers
0-9, letters A-Z, a-z. Press right knob [44] to confirm
first character of the name.
Next characters should be selected in the same way.
To confirm the name of job and go back to the main
menu press button [45] or left knob [43].
USB Memory - when the USB storage
device is connected to USB port user have
access to (Table 10.):
Table 10 USB Menu
Symbol
Save
Load
Save – the following data can be save on a
USB Memory Stick: (Table 11.):
Table 11 Save and restore selection
Symbol
Current Welding Settings
Advanced Parameters Configuration
(P menu)
All welding programs stored in user
memory
M1
One of the welding programs stored in
user memory
M50
24
Figure 25
Description
Description
English