Press right knob [44] to continue.
Figure 84
Press the left knob [43] or button [45] to
exit.
Recording icon will appear on the Status
bar [46].
WARNING
To stop recording please move to Service Menu and
press the Service weld logs icon again.
Weld History – after recording, welding
parameters are saved into the USB device
folder.
To access the Welding history:
Make sure that USB device is connected.
Access to „Configuration" menu.
Go to Service Menu → Weld History
Figure 85
Press right knob [44] to get access of Weld history –
the list of used parameters:
Weld number
Average WFS
Average current [A]
Average voltage [V]
Arc time [s]
Welding program number
Job number/name
English
SnapShot – create a file that contains
detailed
information collected from each module. This
file can be sent to Lincoln Electric Support to
troubleshoot any possible issues that cannot be easily
resolved by the user.
To obtain a SnapShot:
Make sure that USB device is connected.
Go to Configuration → Service Menu → Snapshot
Press the right knob [44] to start Snapshot process.