pressure switch ensures reduced consumption of water in the
jacket and reduced appliance energy consumption overall.
MANOMETER
The appliance is equipped with a manometer, positioned on
the control panel, which indicates the steam pressure inside
the jacket.
SAFETY VALVE
The appliance is equipped with an automatic safety valve (H),
positioned on the countertop, which releases the steam con-
tained in the jacket when steam pressure approaches 50kPa
(0,5 bar).
ANTI-DEPRESSION VALVE
The appliance is equipped with an automatic valve, positioned
on the countertop, which allows air to enter the jacket when the
appliance cools.
3.3 AUTOCLAVE PANS
STEAM DISCHARGE VALVE
The appliance is equipped with an automatic safety valve, built
into the lid, which discharges steam built up in the tank when
steam pressure approaches 0.05 Bar.
4 DISPOSAL OF PACKING AND THE APPLIANCE
4.1 PACKING
The packing is made using environmentally friendly materials.
The plastic recyclable components are:
• the transparent cover, the bags containing the instructions
manual and nozzles ( made of Polyethylene - PE ).
• the straps (in Polypropylene - PP).
4.2 APPLIANCE
The appliance is manufactured 90% from recyclable metals
(stainless steel, aluminium sheet, copper.... ).
The appliance must be scrapped in compliance with current
regulations governing such disposal.
• It must be disposed of properly.
• Make the appliance unusable before scrapping.
INSTRUCTIONS FOR INSTALLATION
REMINDERS FOR THE INSTALLER
The manufacturer will not be liable for any damage or in-
jury resulting from failure to observe the following rules
• Read this manual carefully. It provides important information
for safe installation, use and maintenance of the appliance.
• Installation, conversion to a different type of gas and applian-
ce maintenance must be carried out by qualified technicians
authorized by the manufacturer, in compliance with current
safety standards and the instructions in this manual.
• Identify the specific appliance model. The model number is
detailed on the packing and on the appliance data plate.
• The appliance must be installed in a well-ventilated room.
• Do not obstruct any air vents or drains present on the ap-
pliance.
• Do not tamper with appliance components.
5 REFERENCE STANDARDS AND LAWS
Install the appliance in compliance with current safety stan-
dards.
Install the appliance in compliance with the prescriptions of
EN1717 and the water pollution regulations in force in your
country.
6 UNPACKING
Check the state of the packing and in the event of damage, ask
the delivery person to inspect the goods.
• Remove the packing
• Remove the protective film from the external panels. Use a
suitable solvent to remove any residual adhesive from the
panels
7 POSITIONING
• The overall dimensions of the appliance and the position of
connections are given on the installation diagram at the start
of this manual.
• The appliance can be installed singly or in combination with
other appliances in the same product range.
• The appliance is not suitable for integrated installation.
• Position the appliance at least 10 cm from adjacent walls.
This distance can be reduced in the presence of non-combu-
stible walls or heat-insulated walls.
• Level the appliance by means of the height-adjustable feet.
7.1 APPLIANCE ASSEMBLY WITH BASE, BRIDGE, AND
CANTILEVER SOLUTIONS
Follow the instructions provided with the type of support utili-
zed.
7.2 FIXING THE APPLIANCE TO THE FLOOR
Appliances of 40cms in width installed alone must be fixed to
the floor. Use the flanged feet provided.
7.3 JOINING APPLIANCES TOGETHER IN LINE
• Pull out the control knobs , remove control panel.
• Place the appliances side by side and adjust the tops to the
same height.
• Unite the appliances using the screws.
8 FUMES EXHAUST SYSTEM
Create a fumes exhaust system based on the "Type" of ap-
pliance.The "Type" is stated on the appliance data plate.
8.1 APPLIANCE TYPE "A1"
• Position the "A1" type appliance below an extractor hood to
ensure smoke and fumes generated by cooking are removed
8.2 APPLIANCE TYPE "B21"
• Position the "B21" type appliance below an extractor hood
8.3 APPLIANCE TYPE "B11"
• Fit the "B11" type appliance with a suitable flue, available
from the appliance manufacturer Follow the assembly in-
structions provided with the flue.
• Connect the flue to a 150/155 mm diameter hose, heat resi-
stant to 300°C.
• Vent to the outside or into an efficient flue. The hose length
must not exceed 3 metres.