Replacing the pressure switch
• Remove the front panel
• Remove the control panel.
• Remove and replace the component.
• Re-assemble all parts. For assembly, proceed in reverse or-
der.
Replacing the thermostat
• Remove the front panel
• Remove and replace the component.
• Re-assemble all parts. For assembly, proceed in reverse or-
der.
Replacing the level resistor and the heating element
• Empty the jacket.
• Remove the front panel
• Remove the thermostat bulb from its seat.
• Remove and replace the component.
• Re-assemble all parts. For assembly, proceed in reverse or-
der.
22 CLEANING THE INTERIOR
• Check the condition of the inside of the appliance.
• Remove any built-up dirt.
• Check and clean the fumes exhaust system.
23 MAIN COMPONENTS
23.1
DIRECT HEAT GAS BOILING PAN
• Gas valve
• Main burner
• Pilot burner
• Thermocouple
• Igniter
• Solenoid fill valve
• Energy regulator
• Indicator light
• Control knob
• Safety thermostat
23.2
INDIRECT HEAT GAS BOILING PAN
• Gas valve
• Main burner
• Pilot burner
• Thermocouple
• Igniter
• Solenoid fill valve
• Energy regulator
• Indicator light
• Control knob
• Pressure switch
• Water level resistor
23.3
DIRECT HEAT ELECTRIC BOILING PAN
• Solenoid fill valve
• Energy regulator
• Indicator light
• Control knob
• Safety thermostat
• Heating element
23.4
INDIRECT HEAT ELECTRIC BOILING PAN
• Solenoid fill valve
• Energy regulator
• Indicator light
• Control knob
• Heating element
• Pressure switch
• Water level resistor
51