24
Guy wires may not be included in your fan order. They are intended to restrain the fan's lateral movement and are only
included in fan orders that have extension tubes 4 ft (1.2 m) or longer. Depending on the operational environment (wind,
mounting structure, etc.), guy wires may be needed regardless of extension tube length. If, during operation, any lateral
movement (wobbling) occurs, a guy wire kit should be purchased from Customer Service.
WARNING: Disconnect power to the fan before installing the guy wires.
1. Attach guy wire clamps
Position the guy wire clamps between the two bolts at the bottom of the extension tube. Refer to the diagram below. Secure the clamps
to the extension tube using the Guy Wire Hardware.
Guy Wire Hardware (BAF-Supplied):
a. (2) 1/4-20 x 1" Carriage Bolt
b. (2) 1/4-20 Nylock Flange Nut
Position the guy wire clamps
between the two bolts at the
bottom of the extension tube.
All manuals and user guides at all-guides.com
ESSENCE
Installing Guy Wires
WWW.BIGASSFANS.COM
©2013 DELTA T CORP.
®
Guy Wire Clamps
a
ALL RIGHTS RESERVED
b