WARNING: To reduce the risk of electric shock, wiring should be performed by a qualified electrician! Incorrect assembly
can cause electric shock or damage the motor and the controller! Hazard of electrical shock!
WARNING: The installation of a Big Ass Fan must be in accordance with the requirements specified in this installation
manual and with any additional requirements set forth by the National Electric Code (NEC), ANSI/NFPA 70-2011, and all
local codes. Code compliance is ultimately YOUR responsibility!
WARNING: Exercise caution and common sense when powering the fan. Do not connect the fan to a damaged or
hazardous power source. Do not attempt to resolve electrical malfunctions or failures on your own. Contact Big Ass Fans
if you have any questions regarding the electrical installation of this fan.
The length of the external earth conductor should be such that should failure of the suspension system occur, the
current-carrying conductors are taut before the earth conductor.
After the fan is installed, the safety cable should not be longer than the earth conductor. Should failure of the suspension
system occur, the support of the fan must not rely on the earth conductor.

Power requirements

Essence
is shipped with either a 110–125 VAC motor or a 200–240 VAC motor. The fan's voltage is marked on the fan packaging and
®
on the label on top of the main fan unit. The voltage cannot be changed during installation. Ensure your fan is the correct voltage
prior to beginning installation.
Fan diameter
110–125 VAC, 50/60 Hz, 1 Φ
8 ft (2.44 m)
200–240 VAC, 50/60 Hz, 1 Φ
110–125 VAC, 50/60 Hz, 1 Φ
10 ft (3.05 m)
200–240 VAC, 50/60 Hz, 1 Φ
110–125 VAC, 50/60 Hz, 1 Φ
12 ft (3.66 m)
200–240 VAC, 50/60 Hz, 1 Φ
110–125 VAC, 50/60 Hz, 1 Φ
14 ft (4.27 m)
200–240 VAC, 50/60 Hz, 1 Φ

Wire color chart

North America
100–120 V system
North America
Black, Red, or Blue
208–240 V system
Australia
Brown or Red
All other regions
All manuals and user guides at all-guides.com
Wiring the Fan
Input power
AC Line (L1)
AC Line/Neutral (L2/N)
Black
Red, Blue, or Black
Black or Light Blue
Brown
WWW.BIGASSFANS.COM
ESSENCE
®
Minimum required
Rated
supply circuit size
current
5.7 A
10 A
3.6 A
5.3 A
10 A
3.4 A
4.3 A
10 A
2.7 A
3.8 A
10 A
2.4 A
White
Green or Bare Copper
Green with Yellow Tracer
Blue
©2013 DELTA T CORP.
ALL RIGHTS RESERVED
Earth/PE
29