LEGENDA IMPIANTO ELETTRICO
RIFER.
NOMENCLATURA
SL2
SEL.A CHIAVE 1-0-2 INSTABILE PER DISC.S/
TENSIONE 1 (PONTE) 2 (CALPESTIO)
SL1
SELETTORE A CHIAVE 0-1 STABILE SU 1 ABILITA
DISCESA IN BLOCCO
P4
PULSANTI STOP DISCESA CILINDRI 4
CON PONTE IN BLOCCO/SENZA TENSIONE
P3
PULSANTI STOP DISCESA CILINDRI 3
CON PONTE IN BLOCCO/SENZA TENSIONE
P2
PULSANTI STOP DISCESA CILINDRI 2
CON PONTE IN BLOCCO/SENZA TENSIONE
P1
PULSANTI STOP DISCESA CILINDRI 1
CON PONTE IN BLOCCO/SENZA TENSIONE
PS
PULSANTE DI SALITA
PEM
PULSANTE PER ARRESTO DI EMERGENZA
PD
PULSANTE DI DISCESA
LS3
LAMPADA SPIA LAMPEGGIANTE SEGNALAZIONE
DI RESET
LS2
LAMPADA SPIA BIANCA SOLLEVATORE
ALIMENTATO
LS1
SPIA ROSSA EMERGENZA E BLOCCO
84
REF.
DENOMINATIONS
SL2
SEL.A KEY 1-0-2 UNSTABLE FOR DESC.W/
VOLTAGE 1 (BRIDGE) 2 (TREADABLE PLATFOMR)
SL1
KEY SELECTOR 0-1 STABLE ON 1 ENABLE
BLOCK DESCENT
P4
DESCENT STOP BUTTONS CYLINDERS 4
WITH BRIDGE LOCKED/NO VOLTAGE
P3
DESCENT STOP BUTTONS CYLINDERS 3
WITH BRIDGE LOCKED/NO VOLTAGE
P2
DESCENT STOP BUTTONS CYLINDERS 2
WITH BRIDGE LOCKED/NO VOLTAGE
P1
DESCENT STOP BUTTONS CYLINDERS 1
WITH BRIDGE LOCKED/NO VOLTAGE
PS
UP BUTTON
PEM
EMERGENCY BUTTON
PD
DOWN BUTTON
LS3
BLINKING RESET SIGNALLING LIGHT
LS2
LIFT POWERED UP WHITE INDICATOR LIGHT
LS1
BLOCK AND EMERGENCY RED WARNING LIGHT
0596-M008-0
WIRING SYSTEM
8