BATTERY
The sealed battery does not require any maintenance.
When electrolyte leaks, or other failure of the electrical
system is detected, apply to the HUSQVARNA Dealer.
If the vehicle remains unused for long periods, it is rec-
ommended to disconnect the battery from the electrical
system and store it in a dry place.
- After extensive use, battery should be allowed to run
a slow charging cycle
TE - TXC = 0.6A for 10 hours for 12V-6Ah battery.
TC = 0.4A for 10 hours for 12V-3Ah battery.
- Battery quick charging is only recommended under
extremely urgent conditions, as lead elements life
will be greatly reduced.
TE - TXC = 3A for 1 hour for 12V-6Ah battery.
TC = 4A for 3 hours for 12V-3Ah battery.
BATTERY CHARGER
To gain access to the battery (1):
- Turn pin (2) counter clockwise, and remove saddle (3)
from central retaining screw;
- release battery elastic band (4);
- first remove the BLACK or BLUE negative cable, then
2
the RED positive cable (when reassembling, first con-
nect the RED positive cable, then the BLACK or BLUE
negative cable);
- remove the battery (1) from its housing.
Check, using a voltmeter, that battery voltage is not less
than 12.5 V.
If it is not so, the battery needs to be charged.
Using a battery charger with a constant voltage, first con-
nect the RED positive cable to the battery positive termi-
nal then the BLACK or BLUE negative cable to the battery
negative terminal.
The voltage reaches a constant value only after a few
hours, therefore it is suggested NOT to measure it imme-
diately after having charged or discharged the battery.
Always check the battery charge before reinstalling it on
the vehicle.
Battery shall be kept clean, with greased terminals.
1
3
WARNING*: The battery contains sul-
phuric acid. Avoid contact with skin,
eyes or clothing.
Antidote:
EXTERNAL - Flush with water.
INTERNAL - Drink large quantities of wa-
ter or milk. After milk, take magnesia,
beaten eggs or vegetable oil. Immedi-
ately call a doctor. Eyes: Flush with wa-
ter for no less than 15 minutes and get
prompt medical attention.
WARNING*: Even if not used, battery shall
nevertheless be recharged with a slow
charging cycle at least every 3 weeks.
WARNING*: Batteries produce explosive
gas, ventilate when charging or using
indoors. When using a battery charger,
always connect the battery before turn-
ing on the charger. This procedure pre-
vents sparks at the battery terminals
which could ignite any battery gases.
4
SPECIFICATIONS - OPERATION - MAINTENANCE
EN - 47