6.6 Checking the device

Test according to IEC 60364-6 and the applicable natio-
nal regulations (e.g. in Germany: DIN VDE 0100-600)
Prior to the initial commissioning, execute a test of the
device in accordance with IEC 60364-6 and the appli-
cable national regulations (e.g. DIN VDE 0100-600 in
Germany). The test can be carried out in connection with
the MENNEKES test box and a standard-compliant test
equipment. The MENNEKES test box simulates vehicle
communication. Test boxes are available as accessories
from MENNEKES.
f Perform a standard test before releasing the device.

Operating instructions of the test box.

6.7 Closing the device

T
ATTENTION
Device damage due to crushed components or cables
If components or cables are crushed when closing the
device, damage and malfunctions can occur.
f When closing the device ensure that components or
cables are not crushed.
f If necessary fix components or cables in place.
32
4
Fig. 17: Closing the device
f Lift the front panel (1) upwards and secure it with the
screws (2).
f Fit the upper enclosure part (3) and secure it with the
screws (4) and (5). Use supplied shortened Allen key.
Screw
(2)
(4)
(5)
3
2
2
5
1
Torque
0.5 Nm
1.2 Nm
1.2 Nm