f Connect the charging cable to the vehicle.
For the variant, charging socket with hinged lid:
f Flip up the hinged lid.
f Completely plug the charging plug into the charging
socket on the device.
For the variant, charging socket with shutter:
f Insert the plug into the charging socket on the device.
The contour of the grey ring indicates the orientation
of the plug.
f Turn charging plug 60° counterclockwise to open the
shutter.
f After opening the shutter, insert the charging plug
completely into the charging socket.
9
The charging plug is automatically locked and the
charging process is started.
If charging does not start, the following problem may
exist:
Problem
Interlocking of the
f Check charging socket for
charging plug is not
possible.
f Check charging cable and
Terminating the charging process
T
ATTENTION
Damage to the charging cable
Tensile stress of the charging cable may cause cable
breaks and other damage.
f Only pull the charging cable directly from the socket
outlet.
f End the charging process on the vehicle or by holding
the RFID card in front of the RFID card reader.
f Pull the charging cable out of the charging socket on
the plug.
f Fit the protective cap onto the charging cable.
f Hang or store the charging cable kink-free.
34
Solution
foreign objects.
replace if necessary.
Charging cable cannot be unplugged
If the charging plug cannot be removed, e.g. after a power
failure, the charging plug could not be unlocked in the
device. The charging plug cannot be removed and must
be unlocked manually.
f Have the charging plug unlocked by a qualified electri-
cian via the emergency unlock function.
Î "9.3 Unlock the charging plug"
7.3

Multifunction button

For versions Professional(+) 7,4 / 22 (PnC) only.
7.3.1 Restarting residual current device and circuit
breaker
Fig. 19: Restarting residual current device and circuit
breaker
f Press the multifunction button up to the end position
(> 15 mm).
9
Residual current device and miniature circuit breaker
are switched on again.