Alance; Ave - Cebora 366 Manual De Instrucciones

Ocultar thumbs Ver también para 366:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

CEBORA S.p.A.
7.20 Led AY - Wave.
Selects the welding waveform.
When this led lights display U shows a number
corresponding to the selected waveform (see table).
Default = square - sine (12).
The selection of the waveform may be changed using the
knob Y.
NOTE: The first number that makes up the figure refers to the negative or penetration half-wave, the
second number refers to the positive or cleaning half-wave.
Changing the type of waveform may also reduce noise in AC welding.
7.21 Led AN - Hz.
Frequency of the alternating current (50 ÷ 120 Hz).
7.22 Led AM - Balance.
Is the percentage of the negative (penetration) half-wave in the alternating current period.
Range -10 / 0 / 10 where 0 = 65% (recommended) -10 = 50% and 10 = 85%.
7.23 Led T - > 48V - AC.
In Tig-AC indicates, when lit, the corrected operation of the device to reduce the risk of electric shocks.
3300279-C
11 = square – square
22 = sine - sine
33 = delta – delta
12 = square - sine
13 = square – delta
23 = sine – delta
21 = sine – square
32 = delta - sine
31 = delta – square