Configuration
●
●
7.2.1
Create configuration
If this has not yet been done, a first KC-M20 must be configured with the de-
sired settings. These settings serve as the basis for the configuration of ad-
ditional KC-M20.
The easiest way to configure the charging station is via the web interface.
On the graphical user interface the available settings and selection fields are
provided with short explanations.
Information
Not all settings available in the web interface can be transferred via USB
stick to additional charging stations.
7.2.2
Read out configuration
In order to be able to transfer the configuration of one KC-M20 to additional
KC-M20, the USB stick must be connected to the USB interface (in the con-
nection panel) of the operationally ready and already configured charging
station. The charging station automatically transfers the configuration to the
USB stick and displays the process on the display. When finished, the
charging station indicates that the USB stick can be removed by displaying
"remove usb".
Information
Do not remove the USB stick during the writing process! Otherwise it can-
not be used for another configuration.
7.2.3
Adapt configuration file
To adapt the configuration file, the USB stick must be connected with a com-
puter. The configuration file was saved on the USB stick in the directory
as a
name and parts of the content must be adapted.
Adapting the filename
The filename contains the serial number of the charging station from which
the configuration was read out. This serial number must be deleted from the
filenames.
276
Adapting the configuration file
Import configuration
file. To use the file to configure other charging stations, the file
*.conf
M20
CFG
Configuration manual V1.01