12
UK
ELECTRICAL CONNECTIONS: FASTONS
Faston
Position
1
M1_8 M1_11
2
M1_9 M1_10
3
M1_12 M1_13
PROTECTION FUSES: FASTONS
Position
Value
F1
2A
F2
500 mA
F3
3,15A
ELECTRICAL CONNECTIONS: TERMINAL BOARD
Terminal
Position
M2
M1
M3
M4
Description
Primary connection of 230 VAC transformer (black cables)
Secondary connection of 14 VAC transformer (red cables)
Secondary connection of 22 VAC transformer (blue cables)
Type
FAST
FAST
FAST
Signal
1
NEUTR
2
PHASE
3
EARTH
4
EARTH
5
OPEN MOTOR
6
COM MOTOR
7
CLOSE MOTOR
8
LIGHT 230V
9
LIGHT 230V
10
LAMP 230V
LAMP 230V
11
24Vac
12
13
24Vac
14
E.LOCK 12V
15
E.LOCK 12V
16
+SAFETY
17
SPIA 24Vac
18
SPIA 24Vac
19
START
20
FCC
21
FCA
22
PHOTO 1
23
STOP
24
COM
Description
Secondary transformer protection
Accessory protection
Transformer and motor primary protection
Description
230 VAC power supply
230 VAC power supply
Ground wire connection
Ground wire connection
Motor connection (opening)
Motor common
Motor connection (closing)
Courtesy light output 230V 40W
Courtesy light output 230V 40W
Flashlight output 230 VAC 40W
Flashlight output 230 VAC 40W
24 VAC external accessory power supply (photocells, radio, etc.)
24 VAC external accessory power supply (photocells, radio, etc.)
Positive electric lock
Negative electric lock
Safety device positive power supply with test (see DIP4 SW1), the negative
must be connected to terminal 18
24 VAC warning light output
24 VAC warning light output
START input (N.O.)
Closing limit switch input (N.C.)
Opening limit switch input (N.C.)
PHOTOCELL 1 input (N.C.)
STOP input (N.C.)
COMMON INPUTS/OUTPUTS
BA100
Comes on together with the motor and
goes off 180s after the end of the
movement.
Slow flashing during opening, off during
pause, fast flashing during closing.
Slow flashing during opening, on fixed
during pause, fast flashing during
closing.
Warning: If the limit switches are used
to stop the gate motion, the water ham-
mer must be disabled. See DIP3 SW1