Descargar Imprimir esta página

ARGENTO MiniMax Manual Del Usuario página 20

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 56
Error Code
2
3
4
7
8
10
11
17
18
19
20
Parameter configuration
Press the M button for at least 3 seconds to access the configuration menu and then, quickly press the M button to confirm
the data entered and display the next parameter to be configured.
Select the value for the individual parameter by pressing the + or – buttons and confirm by pressing the M button (quickly to
access the next parameter).
The sequence of parameters that can be configured is shown below:
P1 - Unit of measurement:
Press the + or – buttons to select the unit of measurement for the speed and travel data on the display:
international metric system (Km/h and Km) or British imperial system (MPH and Miles)
P2 - User password ON/OFF display:
available options = on / off
OFF = selecting "off", confirmed by pressing the M button, excludes the user password request (identification code) to allow
the user to access and activate the display and allow full control of all the functions provided for the electrically power
assisted cycle.
The display controls and functions will be immediately accessible after pressing the ON button.
ON = selecting "on", confirmed by pressing the M button, enables the configuration parameter which activates the display and
access to all the functions included for full control of the electrically power assisted cycle only after entering a user password
(identification code).
Display controls and functions, after pressing the ON button, will only be accessible after entering the user password previ-
ously set (P3).
P3 - User password:
Parameter only displayed after the "ON" option has been selected which allows the user to enable the display access
configuration exclusively by entering the password (numeric identification code consisting of 4 digits) previously set and
confirmed as follows:
- select the 4 digits which make up the password by pressing the + and – buttons and confirm them individually by pressing
the ON/OFF button
- confirm the numeric identification code consisting of 4 numbers by pressing the M button.
0000 - System parameter setting password:
if incorrect data on the speed (Km/h and Km) and distance (MPH and Mile) are shown on the display, contact the after-sales
technical support service for assistance: www.argentobike.it/assistenza/
Malfunction description
Malfunction when using the walk assist mode lever
Brake sensor malfunction
Control unit malfunction
Control unit over temperature
High voltage protection (voltage above threshold)
Motor malfunction (excessive power consumption)
Motor hall sensor malfunction
Display-control unit wiring communication malfunction
Display-control unit programming communication malfunction
Brake sensor malfunction
Motor block
19