6.2 STORAGE
The units must be stored according to the following requirements:
Be placed as per specified mounting position of the label;
Be free from vibration and protected from accidental impacts
Be kept at relative humidity <60%, with no intense temperature change, no ultraviolet light and no direct sunlight, and
in case of low temperatures (Tam < -5°C) take special care to avoid shocks and vibration that could damage the
structure.
In the event of prolonged storage/downtime periods (4/6 months) and/or environmental conditions other than those
listed:
Completely fill the unit with oil. The appropriate level should be restored at the time of commissioning of the unit;
We suggest replacing any sealing ring not submerged in lubricant;
Apply plenty of grease and/or suitable protective and waterproofing products in order to prevent deterioration of
shafts and rubber parts;
Periodically rotate the shafts to prevent gluing of the oil seals.
During storage, the units must:
Have the unpainted and machined surfaces protected with oil: the ATEX certification would no longer be
valid in case of surface oxidation.
Once storage operations are completed, units must be cleaned from any residues of dust, rust or other
impurities.