10.2 ATEX - CERTIFIED PRODUCTS
10.2.1 Atex certified products
Frequency, type of checks and related operations are shown in Table MAINTENANCE CHECKS AND
OPERATIONS. Their respect is essential for the maintenance of the ATEX certification.
All operations involving replacement of components must be reported in the "GEAR REDUCER
MAINTENANCE SHEET" (enclosed with the gear reducer), filling in all the fields provided.
Observe the following precautions:
Do not remove the closing cover for any reason;
All operations involving the removal of covers and/or flanges should be made by experts from the
Motovario Technical Centres authorised to Atex maintenance;
Always use official Motovario spare parts. For the request of the components, follow the instructions
given in the spare parts section of the specific unit.
In case you need to replace the oil seals be sure to replace only those externally accessible without
removing covers and/or flanges. For other oil seals, contact an authorised Technical Service
authorised to ATEX maintenance.