Descargar Imprimir esta página

Cooper Lighting Solutions Greengate RC3 Instrucciones De Instalación página 8

Publicidad

Idiomas disponibles

Idiomas disponibles

Room Controller
Wall/Corner Mounting
30'
Mounting
Low Voltage
Base
Wires
Wall Board
Occupancy Sensor Mounted to Wallboard
OAWC sensors can be mounted to the ceiling, junction box
or round fixture with raceway. Optimum mounting height is
8-10 feet. Do not mount over 12 feet.
Mount at fixture height to avoid obstucting view.
Mount the sensor at least 4-6 feet from air supply ducts to
avoid false activation.
N
ote:
Occupancy sensors can also be mounted to an
octagon box or round fixture with raceway.
Drop Ceiling
Mounting
Base
Occupancy Sensor Mounted to Wallboard
www.cooperlighting.com
30'
OAWC-DT-120W &
OAWC-P-120W
Sensor
Low Voltage Wires
Screw, Nut and Washer
Mounting Cover
Sensor
Connecting the Occupancy Sensor to the
Room Controller
Up to two occupancy sensors may be powered from the
Room Controller. Sensors connect using the provided
OCC-RJ45 Input/Output Device and QuickConnect Cables to
ports 3 or 4 on the Room Controller.
Once the sensor is mounted, attach the OCC-RJ45 Input/
Output Device to the sensor leads matching the wire
colors to the label on the input/output device as shown.
Connect the Input/Output Device to one of the two sensor
ports on the Room Controller. Use the shortest lengths of
QuickConnect cable from your QuicKit that will reach the
input/output device location.
Connect a QuickConnect cable between one of
the two Sensor Click & Go ports on the Room
Controller and to one of the Click & Go ports
on the OCC-RJ45 Input/Ouput Device.
OCC-RJ45
(Input/Output Device)
Blue
Red
Black
Brown
QuickConnect Cable
(Class 2)
6
Switchpack
White
Red
Receptacle
BMS/Out
5
Black
Sensors
Green
Sensors
Slider
Station
4
Wallstations
-
A/V
+
Mode
-
3
Demand
+
Response
-
Alert
+
Mode
-
Time
+
Clock
2
1
Energy Options DIP Switch
Demand Response
Occupancy
Not Used
1 2
3
4
Default 10%
Occ
20%
Vac (default)
30%
40%
0-10V Dimming Outputs
-
-
-
+
+
+
Dimmer 3
Dimmer 2
Dimmer 1
Dimmer 3
-
Dimmer 2
-
Dimmer 1
-
+
+
+
0-10V Dimming
Vacancy Mode
Occupancy Mode
(Default)
All Relays On 50%
4
4
3
3
* Dip Switches 3&4 up triggers programmable Scene 6, which
can be adjusted using the Personal Remote (HHPR-RC)
N
ote:
For spaces that need more than two occupancy
sensors see the app note: "Room Controller applications
for additional occupancy sensors," on our website.
Greengate
4
3
Occupancy Mode
All Relays On to
daylight level *
4
3
9850-000362-06 page 8
October 2022

Publicidad

loading