Solter aeroprocess 4200 DV Manual De Instrucciones página 51

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

ER16
ER17
ER18
ER19
ER20
ER21
ER22
ER23
ER24
The following table shows the possible alarms that can appear during operation of the machine. These alarms DO
NOT imply a machine malfunction. They are displayed in the event that the operating cycle is exceeded or due to a
lack of proper maintenance. Alarms in the 10-15 range must be validated manually by pressing the main control but-
ton, once their causes have been checked. Do not validate the alarm without checking its cause and then carry out
the appropriate maintenance. If the machine is kept operating for too long with alarms displayed, this could cause a
failure. This failure will not be covered by the machine guarantee due to an inadequate maintenance.
ALARM code
A.01
A.02
A.03
A.04
A.05
A.06
A.07
A.08
A.09
SOLTER
SOLDADURA S.L.
Corrupt operating parameters.
Synchronization between main control unit and user interface pending.
Detection of different user interface from the original.
User interface not supported.
Data memory not initialised.
Compatibility verification between user interface and main control is incorrect.
Error in factory calibration.
Wrong serial number.
Failure in the software updating process of the main control unit.
Excess temperature at the main inverter stage. Wait until the machine regains a safe
temperature at this stage. Ensure vents are not clogged.
Excess temperature at the output power stage. Wait until the machine regains a safe
temperature at this stage. Ensure vents are not clogged.
Excess temperature at the output power stage. Wait until the machine regains a safe
temperature at this stage. Ensure vents are not clogged.
Excess temperature at the auxiliary stage. Wait until the machine regains a safe tempera-
ture at this stage. Ensure vents are not clogged.
The machine has detected voltage peaks in the mains supply. If you continue working
with an unstable mains supply, it can cause internal damage. Please check that the
mains supply is correct.
The machine has detected a supply voltage too low to ensure optimum performance.
Please check that the mains supply is correct.
The machine has detected an unstable supply voltage. This situation can be caused by a
defect in the connections of the power supply terminals or by powering the machine with
an unsuitable autonomous generator.
Overconsumption alarm. This alarm automatically disappears after a few minutes. Wait
until the machine returns to its normal state.
Overtemperature alarm in remote liquid cooling unit. Wait until the machine regains a
safe temperature in this unit. Ensure vents are not clogged.
Description
AEROPROCESS
24

Publicidad

Tabla de contenido
loading

Tabla de contenido