Descargar Imprimir esta página

Saivod SAP1218 Manual De Instrucciones página 84

Publicidad

Idiomas disponibles

Idiomas disponibles

Introduction for buttons on remote controller
Note:
For preventing cold wind, after starting up heating mode, indoor fan will blow fan
afterdelaying 1-5min. (Details time is decided by indoor ambient temperature)
Temperature setting range on remote controller: 16℃ -30℃ . Fan speed setting
range: auto, low speed, medium speed and high speed.
3
"+" or "-" button
● After each pressing of "+" or "-" button, it can increase or decrease set temper-
ature 1℃ . Hold "+" or "-" button, 2s later, set temperature on remote controller
will change quickly. After reaching to your required time, loosen the button.
Temperature indicator on indoor unit will also change accordingly. (Temperature
can't be adjusted under auto mode)
● Under TIMER ON, TIMER OFF or Clock setting, you can press "+"or "-" button to
adjust time. (Refer to TIMER button for details)
4
FAN button
Pressing this button can set fan speed circularly as: auto (AUTO), low(
medium(
), high(
Note:
● Under AUTO Speed,IDU fan motor will adjust the fan speed (high, medium or
low speed) according to ambient temperature.
● Fan speed under dry mode is low speed.
5
button
● Press this button to start or stop up & down swing function.The remote controller
defaults to simple swing condition.
● Press + button and
simple swing and static swing;
● In static swing condition, pressing
changes as below:
● If the unit is turned off during swing operation,the louver will stop at present
position.
).
Auto
button at the same time at unit OFF to switch between
no display
(horizontal louvers stops
at current position)
blinks for 2 seconds.
button, the swing angle of up & down louver
),

Publicidad

loading

Este manual también es adecuado para: