1.31. Selection of the preset
The system provides 3 pre-charged settings that can be selected though the display button.
Hereunder the description of the procedure.
1.Keep the display button pressed and switch the system ON. Keep the button pressed till the display starts blinking
(one blink from white LEDs).
2.System is now setted on PRESET1. Briefly press the button, system will switch on PRESET 2 and the display will blink 2 times.
Briefly press the button again, the system will switch on PRESET 3 and the display will blink 3 times.
It is possible to change presets as a Preset 1 ➔ Preset 2 ➔ Preset 3 ➔ Preset 1 ..... loop.
3.Switch the system OFF. The last selected preset is now active.
1.31.1. Presets chart
Selection blink code
How to use the SIS Easy anti-collision device
1.32.
Important safety rules
The SIS Easy anti-collision device is not a substitute for the operator manoeuvring vehicles forwards or in reverse. Such
vehicles must be driven and manoeuvred by personnel authorised to do so and adequately trained in accordance with
the applicable regulations.
Since the SIS Easy anti-collision device is merely an aid for manoeuvring a vehicle forwards or in reverse, the driver must
always look in the direction of travel, and make sure for himself that there are no hazards.
The Buyer/User must provide the users of industrial vehicles using the SIS Easy anti-collision device with information and
training on the functions.
While driving or manoeuvring a forklift truck on which an SIS Easy anti-collision device is mounted, it is mandatory to
proceed at a moderate speed to ensure the best possible performance of the system.
Pagina 46
MNL.000001
Rev.03 25.09.2019
Preset
Distances
Yellow : 2 m
1
Red ; 1 m
Yellow : 2,5 m
2
Red : 1,5 m
Yellow : 3,5 m
3
Red : 2 m