Descargar Imprimir esta página

Angelo Po 1N1BR2G Manual De Uso página 105

Sartén de gas

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

Important
Those authorised to carry out this operation
must have experience acquired and certifi ed
in the specifi c sector, must make the connec-
tion to the proper standards, and must com-
ply with all the relevant regulations and legi-
slation. Once the connection has been made,
before the appliance is put into operation a
general check must be made to ensure there
are no gas leaks.
To make the connection, connect the mains line
to the appliance's connection pipe, fi tting a shut-
off tap (A), to allow the gas supply to be cut off
when necessary.
Important
The tap (A), not supplied with the appliance,
must be installed in an easily accessible posi-
tion and its status (on or off ) must be obvious
at a glance.
Important
Make the connection in compliance with the
relevant legal requirements, using appropria-
te and recommended materials.
Position the appliance
)
underneath the hood (A)
(see diagram).
Important
The gas supply tap (A) must
open automatically when
the fan of the extraction sy-
stem is switched on.
_inst_GB
GAS CONNECTION
CONNECTION OF FUME EXHAUST VENT
A
A
Important
The gas supply pipe must comply with the na-
tional requirements in force and must be peri-
odically examined and replaced if necessary.
Connecting to a fan extractor hood
To carry out this operation, proceed as follows.
A
-
-
GB
ENGLISH

Publicidad

loading

Este manual también es adecuado para:

1n1br3g2n1br2g2n1br3g1t1br2g1t1br3g2t1br2g ... Mostrar todo