Important
Before making any type of adjustment, activa-
te all the safety devices provided and decide
whether staff at work and those in the vicinity
should be informed. In particular, turn off the
gas and water supply taps, cut off the electrici-
ty supply using the master switch and prevent
access to all devices which might cause unex-
pected health and safety hazards if turned on.
Important
This adjustment is only required if the type
of gas to be connected is diff erent from that
used for testing after the conversion pro-
cedure has been carried out (see page 13).
Natural and bottled gas
Proceed as follows.
Turn off the gas supply tap and switch off the
)
main electricity supply.
Remove the knob (B).
)
Undo the screws (C) and remove the control
)
panel
.
(D)
Undo the screw (E) of the pressure connection.
)
Connect the pressure gauge (F) to the pressure
)
GB
test point.
_inst_GB
ADJUSTMENTS
INSTRUCTIONS AND WARNINGS FOR ADJUSTMENTS
ADJUSTING GAS VALVE MINIMUM SETTING
B
C
Caution - Warning
Adjustments must be carried out by authori-
sed, qualifi ed staff , in accordance with the re-
levant legal requirements.
Before making this adjustment, check that
the gas supply pressure is the same as the ra-
ted pressure for the type of gas in use (see ta-
ble at back of manual).
Turn the guard (G) anticlockwise and remove it.
)
Turn the gas supply tap back on and switch the
)
main electricity supply back on.
Light the burner and turn the control knob (A)
)
to the maximum temperature setting.
Turn the control knob (A) anti-clockwise to the
)
lowest power setting. You will hear the click as
the device switches.
A
D
C
-
-