The setting of the pressure sensor does not depend on the pressure to be obtained, but on the sensor to be fitted on the
.
system
6.5.8
MS: Measurement system
Sets the system of units of measurement between international and Anglo-American. The values displayed are shown in Table 18.
Value
Restart
Temperature
Flow
6.5.9
FI: Flow sensor setting
This enables setting of operation as described in Table 19.
Value
0
without flow sensor
1
single specific flow sensor (F3.00)
2
multiple specific flow sensor (F3.00)
3
manual setting for a general single pulse flow sensor
4
manual setting for a general multiple pulse flow sensor
In the case of multi inverter operation, use of multiple sensors can be specified.
6.5.9.1
Operation without flow sensor
When the setting without flow sensor is selected, the FK and FD settings are automatically disabled as these parameters are not
necessary. The parameter disabled message is indicated by an icon showing a padlock.
It is possible to choose between 2 different operating modes without flow sensor by means of the parameter FZ (see par. 6.5.12):
Minimum frequency mode: this mode allows you to set the frequency (FZ) below which it is considered that there is zero flow. In this
mode the electropump stops when its rotating frequency falls below FZ for a time of T2 (see par. 6.6.3).
IMPORTANT: An incorrect setting of FZ causes:
1.
If FZ is too high, the electropump could cut out even in the presence of flow and then start again as soon as the pressure
falls below the restarting pressure (see 6.5.5). So there could be repeated episodes of switching on and off, even quite close
together.
Pressure sensor settings
Type of sensor
Table 19: Pressure sensor settings
Units of measurement displayed
International unit of measurement
Table 20: Unit of measurement system
Type of use
Table 21: Flow sensor settings
ENGLISH
Information
501 R 16 bar
501 R 25 bar
501 R 40 bar
4/20 mA 16 bar
4/20 mA 25 bar
4/20 mA 40 bar
bar
°C
l / min
Flow sensor setting
106
Full scale [bar]
16
25
40
16
25
40
Anglo-American unit of measurement
°F
gal / min
Notes
default
Full scale [psi]
232
363
580
232
363
580