English
be operated only when a protective conductor has been connected to the protective earth.
The exchangeable kit must be designed to ensure that tools with a diameter of > 2.5 mm are un-
able to come into contact with live component parts. In addition, connections conducting voltage
into the interior must not be present if the interior contains live parts. Accordingly, the standard
exchangeable kit must be equipped with an additional cover plate as contact protection. This plate
is used to cover all of the screws in the pressure frame plate and seal off all machined holes.
WARNING
L
ETHAL ELECTRIC SHOCK
Deadly electrical voltage at the test probes and interface components for > 25 VAC voltage
and > 60 VDC voltage!
Apply voltage only if all of the following conditions are met:
Always equip the test fixture with the correct protective conductor wiring, a protective
conductor connection and an integrated safety switch before carrying out testing work.
5.3)
ESD connection
An ESD connection is available for components at risk from electrostatic discharge. With this de-
sign, all electrically-conductive components are connected to the ESD connection on the rear pan-
el of the test fixture. The exchangeable kit's probe plate unit is connected using a spring-loaded
discharge probe in the test fixture's base system. The ESD connection in the exchangeable kit's
©
INGUN: Subject to technical changes without notice. E&OE.
Protective conductor connection to the test fixture
Shock-proof protection on the exchangeable kit
!