Inspect the hydraulic parts and cutting blades. Clean them if necessary.
WARNING
Presence of cutting impeller.
Risk of pinching, cutting or amputating fingers or other
body parts.
 Keep away from moving parts.
Advise and/or train operating staff.
7.3 COLLECTING TANK
Inspect the tank, check for possible deposits, the presence of grease
and foreign bodies. Thoroughly clean the tank and remove foreign bod-
ies.
7.4 MAINTENANCE CONTRACT
As with any technical, high-performance equipment, Sanicubic SC
pumping stations must be maintained to ensure a sustainable level of
performance. We recommend you take out a maintenance contract
with a qualified company to carry out regular inspection and mainte-
nance work. For more information, please contact us.
8. INCIDENTS, CAUSES AND SOLUTIONS
DANGER
Disconnect electrical power before working
on the unit!
NOTICE
Never unscrew the 4 hex head screws no. 16
(see Appendix B): this will cause oil leakage,
damage to the mechanical seal and invalidate
the warranty.
- To dismantle the motor block only, unscrew the 4 no.
13 screws.
- To dismantle the whole pump, loosen the 4 nuts no. 23.
Malfunction
Cause
Motor does not rotate.
Too low voltage, voltage
missing.
Incorrect power
connection.
Power cable defective.
Fault on the capacitor -
only with single-phase
station.
Impeller blocked.
Motor protection switched
off due to overheating,
blockage, voltage error.
Control error.
Pneumatic hose or
connection leaky.
Motor defective.
Motor rotates, but does not
Impeller clogged or worn.
deliver.
Check valve clogged.
Shut-off valve clogged or
closed.
Pressure line clogged.
Intake socket clogged.
Direction of rotation
incorrect.
Water shortage in the tank. Switch off/Customer service.
Tank ventilation clogged.
Pump housing ventilation
clogged.
Motor rotates, but
Voltage wrong or
switches off.
fluctuates.
Overcurrent release
incorrectly set.
Power consumption too
high.
Motor does not switch off.
Control error.
9. STANDARDS
The lifting stations Sanicubic SC conform to Low Voltage, EMC and
Machinery directives, and to EN 12050-1 Construction Products Reg-
ulation.
10. GUARANTEE
As the manufacturer, we provide a 24-month warranty for this appli-
ance from the date of purchase.
Your reciept of purchase is valid as proof. Within this warranty period,
we will, at our discretion, remedy all defects attributable to material or
manufacturing faults by repair or replacement free of charge.
Damage caused by improper installation and/or use, and wear and tear
is excluded from the warranty. We shall not be liable for consequential
damage caused by failure of the device.
Remedies
Check voltage supply.
Correction.
Replacement (after-sales
service).
Replacement (after-sales
service).
Clean.
Check/Customer service.
Check/Customer service.
Check/Customer service.
Replacement (after-sales
service).
Clean/Replace.
Clean.
Clean/Open.
Clean.
Clean.
Correction.
Clean.
Clean.
Correction/Customer
service.
Set properly.
Customer service.