7.3
Parameter setting and display
To go into the parameter menu:
– from the selected mode (eg. WINTER)
– press the buttons
<
and
same time until "tS" (installer) appears on the 2 digits of the
display which alternate with "0.1" (parameter number) and a
(set value)
"5"
– press the button
>
to scroll up the list of parameters and then
<
to scroll down the list
NOTE:
holding the buttons
scrolling movement.
7.4
List of parameters
Motor
No.
Description
type
tS
0.1
Index showing boiler power in kW
tS
0.2
Hydraulic configuration
tS
0.3
Gas Type Configuration
tS
0.4
Combustion configuration
tS
0.8
External sensor value correction
tS
0.9
Ignition fan speed
tS
1.0
Boiler Antifreeze Threshold
External Sensor Antifreeze Threshold
tS
1.1
-- = Disabled
tS
1.2
Heating Curve Incline
Minimum Heating Temperature
tS
1.3
Adjustment
Maximum Heating Temperature
tS
1.4
Adjustment
tS
1.5
Maximum power heating
tS
1.6
Heating Post-Circulation Time
tS
1.7
Heating Pump Activation Delay
tS
1.8
Heating Re-ignition Delay
Domestic Hot Water Modulation with
tS
1.9
Flow meter
tS
2.0
Maximum power domestic hot water
102
o
(approximately 5 seconds) at the
>
or
<
increases the speed of the
1 = storage tank with thermostat or heating only
DOMESTIC HOT WATER - HEATING
– once the required parameter has been reached, press the
button
o
for approximately 3 seconds to confirm and access
the set value which will then flash and can then be modified
– to modify the value in the permitted range, press the buttons
>
to increase it or
– once the required value has been reached, press the button
o
to confirm.
When all the parameter modifications have been made, exit the
parameter menu by pressing and holding down the buttons
and
o
at the same time
initial screen is displayed.
Range
CONFIGURATION
4 = 40 kW
0 = rapid
2 = hot water tank with sensor
3 = bithermic
4=instant with solar power input
5 = open vent
6 = boiler with heat pump
0 = G20
1 = G30/G31
0 = sealed chamber with combustion control
1 = open chamber with smoke thermostat
2 = Low Nox
-5 .. +5
80 .. 160
0 .. +10
-9 .. +5
0 .. 80
20 .. Par tS 1.4
Par tS 1.3 .. 80
0 .. 100
0 .. 99
0 .. 60
0 .. 60
0 = Disabled
1 = Enabled
0 .. 100
<
to decrease it
for approximately 5 seconds until the
U/M
Step
-
1
-
1
-
1
-
1
°C
1
RPMx25
1
°C
1
°C
1
-
1
°C
1
°C
1
%
1
seconds
1
x 10
seconds
1
x 10
Min
1
-
1
%
1
EN
<
Default
4
0
0
0
0
128
3
-2
20
20
80
100
3
0
3
1
100

Publicidad