5.7
Sensors
The sensors installed have the following characteristics:
– Dual sensor (thermal safety/output) NTC R25°C; 10kΩ β25°-
85°C: 3435
– domestic hot water sensor NTC R25°C; 10kΩ β25°-85°C: 3435
– External temperature sensor NTC R25°C; 10kΩ β25°-85°C:
3435
Correspondence of Temperature Detected/Resistance
Examples of reading:
TR=75°C → R=1925Ω
TR=80°C → R=1669Ω.
TR
0°C
1°C
2°C
3°C
0°C 27279
26135
25044
24004
10°C
17959
17245
16563
15912
20°C
12090
11634
11199
10781
8313
8016
7731
7458
30°C
40°C
5828
5630
5440
5258
50°C
4161
4026
3897
3773
60°C
3021
2928
2839
2753
70°C
2229
2164
2101
2040
1669
1622
1577
1534
80°C
90°C
1266
1232
1199
1168
100°C
973
5.8
Expansion vessel
The expansion vessel installed on the boilers has the following
characteristics:
Description
Total capacity
Prefilling pressure
Useful capacity
Maximum system content (*)
(*) Conditions of:
Average operating temperature 70°C (with high tempera-
ture system 80/60°C)
Start temperature at system filling 10°C.
m
CAUTION
– For systems with water content exceeding the max-
imum system content (as indicated in the table) an
additional expansion vessel must be prearranged.
– The difference in height between the relief valve
and the highest point of the system cannot exceed
6 metres. If the difference is greater than 6 metres,
increase the prefilling pressure of the expansion
vessel and the system when cold by 0.1 bar for each
meter increase.
88
4°C
5°C
6°C
7°C
8°C
9°C
23014
22069
21168
20309
19489
18706
15289
14694
14126
13582
13062
12565
10382
9999
9633
9281
8945
8622
7196
6944
6702
6470
6247
6033
5082
4913
4751
4595
4444
4300
3653
3538
3426
3319
3216
3116
2669
2589
2512
2437
2365
2296
1982
1925
1870
1817
1766
1717
1491
1451
1411
1373
1336
1300
1137
1108
1079
1051
1024
998
MIA HE C10
U/M
40
l
9,0
kPa
100
bar
1,0
l
5,2
l
120
5.9
Circulation pump
The flow-head performance curve available for the heating sys-
tem is shown in the graph below.
RESIDUAL HEAD (mbar)
700
600
500
400
300
200
100
0
0
200
400
600
m
CAUTION
The appliance is equipped with a by-pass which en-
sures water circulation in the boiler when the thermo-
static valves or cocks are used in the system.
EN
40
800
1000
1000
1200
WATER FLOW RATE (l/h)
Fig. 13

Publicidad