5
DESCRIPTION OF THE APPLIANCE
5.1
Characteristics
MIA HE C10
are last generation condensing wall mounted boilers
which Sime has produced for heating and domestic hot water
production. The main design choices made by Sime for the MIA
boilers are:
HE C10
– the total pre-mix microflame burner combined with a steel
heat exchanger for heating and a rapid heat exchanger for
DHW
– the sealed combustion chamber which can be classified "Type
C" or "Type B" in relation to the room where the boiler is in-
stalled, depending on the smoke outlet configuration adopted
during installation
– the microprocessor electronic control board, which makes
the heating and domestic hot water production system eas-
ier to manage and offers the option to be connected to room
thermostats or to a remote control (with Open Therm proto-
col) and also to an external sensor. Where connected to an
external sensor, the boiler temperature varies on the basis
of the external temperature, according to the selected opti-
mal climatic curve. This provides significant energy and cost
savings.
Other special features of the MIA HE C10 boilers are:
– the anti-freeze function which activates automatically if the
temperature of the water inside the boiler falls below the
threshold of the value set at parameter "tS 1.0" and , if there
is an external sensor, if the external temperature falls below
the threshold of the value set at parameter "tS 1.1".
– the anti-blocking function of the pump and diverter valve, this
activates automatically every 24 hours if no request for heat
has been made
– the chimney sweep function lasts 15 minutes and makes the
job of the qualified technician easier when measuring the pa-
rameters and combustion efficiency
– screen display of the operating and self-diagnostic parame-
ters with error code display when the fault occurs. This makes
repair interventions easier and allows appliance operation to
be restored correctly.
5.2
Check and safety devices
The MIA HE C10 boilers are equipped with the following check
and safety devices:
– thermal safety thermostat 100°C
– 3 bar relief valve
– pressure transducer
– heating water pressure switch
– delivery sensor
– DHW sensor
– smoke flue gas probe.
d
IT IS FORBIDDEN
To commission the appliance with safety devices
which do not work or which have been tampered with.
a
WARNING
Safety device may only be replaced by professional
qualified personnel using Sime original spare parts.
84
5.3
Identification
The MIA HE C10 boilers can be identified by means of:
this is located on the outside of the packag-
1
Packaging label:
ing and provides a code, the serial number of the boiler and
the bar code
2
Energy Efficiency Label:
this is positioned on the outside of
the packaging to notify the User of the level of energy sav-
ings and reduced environmental pollution produced by the
appliance
3
Technical Data Plate:
this is located on the side of the ap-
pliance and provides the technical data, appliance perfor-
mance and any other information required by law.
1
MIA HE ...
2
I
II
A
++
A
A
+
B
A
C
B
D
C
D
E
E
F
F
G
G
kW
dB
2015
811/2013
Cod. 6244745
3
Fonderie SIME S.p.A.
Via Garbo, 27 - 37045 Legnago - VR (Italy) - Tel. +39 0442 631111
CALDAIA A CONDENSAZIONE - CONDENSING BOILER - CALDERA DE CONDENSACION - CALDEIRA A
CONDENSACAO - CHAUDIERE A CONDENSATION - CONDENSATIEKETEL - GASBRENNWERTKESSEL -
- KONDENZACIJSKI KOTEL - PLYNOVÝ KONDENZ
NI KOTEL - CONDENSARE
CAZAN - KOCIOL KONDENSACYJNY - KONDENZÁCIÓS KAZÁNOK -
MIA HE 25
8116600
9999999999
2018
PIN n.
1312CR6307
1312
2,45
L
G20
G31
G20
G31
Q max =
20,00
kW
20,00 kW
Q min =
4,00
kW
4,00 kW
n
n
P max 80-60°C =
19,60
kW
19,60 kW
P min 80-60°C =
3,80
kW
3,80 kW
n
n
P max 50-30°C =
21,20 kW
21,20 kW
P min 50-30°C =
4,20 kW
4,20 kW
n
n
PMS =
3
bar 0,3 MPa
T max =
85
°C
---
L
G20
G31
G20
G31
Q
max =
24,00
kW
24,00 kW
Q
min =
4,00
kW
4,00 kW
n
w
n
w
PMW =
7
bar 0,7 MPa
T max =
60
°C
11,0
l/min (EN 13203)
230V~ - 50Hz - 84 W
IP X5D
NOx class 6
G20 20 mbar
GR-SI-CZ-SK-LT-HR
II2H3P
G20/G31 20/37 mbar (2/3,7 kPa)
B23P-B53P-C13-C43-C53-C63-C83
PL-RO
G20 20 mbar (2 kPa)
B23P-B53P-C13-C43-C53-C63-C83
I2E
HU
I2H
G20 25 mbar (2,5 kPa)
B23P-B53P-C13-C43-C53-C63-C83
G31 37 mbar
MADE IN ITALY
m
CAUTION
Tampering with, removing or failing to display the
identification plate or carrying out any other operation
which does not allow safe identification of the product
or which may hinder installation and maintenance op-
erations.
EN
1
2
3
Fig. 10