Preliminary checks
a
WARNING
– Should it be necessary to access the areas in the
bottom part of the appliance, make sure that the
system components and pipes are not hot (risk of
burning).
– Before replenishing the heating system, put on pro-
tective gloves.
Commissioning of the MIA HE C10 boiler must be carried out by
professionally qualified Personnel after which the boiler can op-
erate automatically. It may however be necessary for the User to
start the appliance autonomously without involving a technician:
for example, after a holiday . In these cases certain checks and
the following operations must be carried:
– check that the gas isolation and water system valves are open
– using a pressure gauge (1), check that the heating system
pressure when cold is 1-1.2 bar . If this is not the case, open
the filling valve (2) and restore the heating system pressure
until the pressure gauge (1) shows a reading of 1-1.2 bar
– close the filling valve (2).
2
1.3
Ignition
After having carried out the preliminary checks, perform the
following to start the boiler:
– set the main system switch to "ON"
ON
1
Fig. 2
Fig. 3
– on the display, check that the operating mode on the display
is "SUMMER"
l
and if necessary select it by pressing and
holding the button
s
for at least 1 second. the value of the
delivery sensor detected at that moment will appear on the
display
– open one or more than one hot water tap. The boiler will work
at maximum power until the taps are closed.
Once the boiler has been commissioned in "SUMMER mode"
"WINTER mode"
n
can be selected by pressing and holding the
button
s
for at least 1 second. the value of the heating water
temperature detected at that moment will appear on the dis-
play. In this case it is necessary to adjust the air thermostat/s to
the required temperature or if the system has a chrono-thermo-
stat, check that this is "active" and adjusted.
1.4
Adjusting the delivery temperature
Should you wish to increase or decrease the boiler delivery tem-
perature, turn the dial
t
to the desired setpoint. The value can
be set to between 20°C and 80°C.
1.5
Adjusting the domestic hot water temper-
ature
Should you wish to increase or decrease the domestic hot water
temperature, turn the dial
r
can be set to between 10°C and 60°C.
Fig. 4
to the desired setpoint. The value
Fig. 5