4�2
Protections
4�2�1
Lock protection
If the welder malfunctions, a warning message may appear on display 1. This identifies the type of defect. If the
message is still present after turning the machine off and on, contact the assistance service.
4�2�2
Thermal protection
This device is protected by a thermostat which prevents the machine from operating if the allowable temperatures are
exceeded. Under these conditions, the fan continues to operate and display 1 shows the flashing WARNING code tH.
5
INSTALLATION AND START UP
The system must be installed by qualified personnel. Carefully read the "Staff obligations and qualifications" section
in General Warnings code 3301151.
During transport of the device, ensure that applicable national and regional accident prevention guidelines and
regulations are observed. This applies in particular to guidelines concerning transport and shipping risks.
Carefully read the "Lifting and transporting" section in General Warnings code 3301151
Tipping a device over may endanger life! Position the device stably on a solid, flat base.
A maximum angle of inclination of 10° is allowed. Do not lift or transport live devices. The machine should not be
positioned on sloping planes, to prevent tilting or any uncontrolled movement.
To move the power source, fit the missing rear wheels and adhere scrupulously to the following instructions.
Disconnect the device from the power supply before moving it.
During transport of the device, ensure that all applicable local accident prevention guidelines and regulations are
observed.
After transport or relocation and before operating, a visual inspection must be performed on the device to check for
any damage.
Ensure any damage is repaired by qualified CEBORA authorised technical assistance staff before operating the
device.
The capacity of the lifting device must be at least 20% greater than that of the load to be lifted.
When lifting the power source and the wire feeder, use only the eyebolts located on the top of the power source and
on the wire feeder spool support.
All harnessing devices (straps, buckles, chains, etc.) that are used together with the device or its components must
be checked at regular intervals
(e.g. for mechanical damage, corrosion or alterations caused by environmental factors). Check intervals and scope
must at least comply with national standards and directives in force from time to time.
3301291