7�1�3
Setting welding parameters
0.0
0.0
7�2
Main menu
7�2�1
Selecting the welding process
7�2�2
Selecting wire type, diameter and welding gas
MATERIAL pushbutton can be used to select wire type, diameter and welding gas
The
7�2�3
Selecting process parameters
Parameters
The
pushbutton can be used to set the various process parameters:
3301291
3301291-EN
Adjusting
inductance� This can be selected using pushbutton D. This function can be used
to switch between a narrow, hard arc with deep penetration (negative values) and a broad,
smooth arc (positive values). The adjustment can range between +/- 9.9, 0 is the factory
setting�
Adjusting arc length� This can be selected using key E. If necessary, arc length (welding
voltage) can be corrected by +/- 9.9 V for the specific welding job, 0 is the factory setting.
This can be selected using pushbutton F
Select to enter the Main Menu�
The PROCESS pushbutton can be used to select the MIG/MAG or MMA process.
After selecting the MIG
transfer type: MIG Pulse, MIG Pulse HD, MIG Short, MIG Short HD and MIG
Manual.
To confirm the selection, press knob 2 or key
welding process, with knob 2 you can select the arc
■ Arc length correction
This can be selected using pushbutton E
Turn knob 2 to select the parameter and confirm the
selection by pressing the same knob.
Adjust the value by turning knob 2.
To confirm the selection, press knob 2 or key
Press the DEF key to restore factory settings.
■ Inductance correction
This can be selected using pushbutton D
Turn knob 2 to select the parameter and confirm the
selection by pressing the knob.
Adjust the value by turning knob 2.
To confirm the selection, press knob 2 or key
Press the DEF key to restore factory settings.
.
To confirm the selection,
press knob 2 or key
.
.
53