Calibration
7�5
Job Menu
A welding programme and its parameters (process, ignition, mode etc.) can be saved on the JOB page.
The available JOBS are numbered and range from 1 to 99.
The operations that can be carried out on a JOB are listed below:
Save the Job
Retrieve the Job
Delete the Job
Copy the Job
Rename the Job
7�5�1
Saving a welding JOB
7�5�2
Modifying a welding JOB
7�5�3
Deleting a welding JOB
60
Use knob 2 to select Calibration mode.
The purpose of this function is to provide specialised
personnel with guidance on how to calibrate Cebora
power sources in compliance with IEC EN 60974 -14.
The power source calibration must be carried out by
qualified personnel.
For
instructions,
contact
Assistance Service.
Using knob 2, select the JOB memory position.
Press the
key to save the Job
A description of the saved process will now appear in
the selected position.
Select the relevant JOB by turning knob 2
Retrieve by pressing pushbutton
Modify the welding parameters.
Select JOB using the G pushbutton
Overwrite the previous JOB or create a new one by
selecting a free memory position and pressing
Select the JOB memory position by turning knob 2
Press pushbutton
and the JOB will be deleted.