10
ERROR CODES
Error management is divided into two categories:
1)
Hardware errors [E]. These cannot be reset and require the power source to be restarted. They are displayed on
the screen with a red background.
2)
Alarms [W] linked to an external condition that can be reset by the user and does not require the power source
to be restarted.
These are displayed on the screen with an amber background.
Code
Type
EEPROM error detected by the power source
2
[E]
internal board
General fault error detected by the power
3
[E]
source internal slave board
Communication error detected by master
6
[E]
panel board on CAN-bus
Communication error between Slave board
9
[E]
and Master board
10
[E]
Power output nil (I=0A, V=0V)
11
[E]
Overload at output
Undervoltage error detected on inverter
14
[E]
control board.
17
[E]
Invalid or unrecognised power source model.
20
[E]
Interlock signal absent
22
[E]
Hardware key not readable
Error during reprogramming of the EPLD or
24
[E]
FPGA
25
[E]
Excessive primary winding current error
26
[E]
Time not set or battery flat
64
Error Description
Action
Switch the power source off and on. If the
problem persists, contact technical assistance
Switch the power source off and on. If the
problem persists, contact technical assistance
Switch the power source off and on. If the
problem persists, contact technical assistance
Check connection between power source
and wire feeder. Switch the power source on
and off. If the error persists, contact technical
assistance.
Hardware error, contact technical assistance.
Probable break in inverter circuit of primary
winding or secondary unit
Hardware error, contact technical assistance.
Check machine supply voltages. If the problem
persists, contact technical assistance.
Check the wire feeder - power source
combination is correct. Switch the power
source on and off. If the error persists, contact
technical assistance.
Switch the power source off and on. If the
problem persists, contact technical assistance
Switch the power source on and off. If the error
persists, contact technical assistance.
Switch the power source off and on. If the
problem persists, contact technical assistance
Probable break in output diodes or primary
winding inverter circuit. Switch the power
source on and off. If the error persists, contact
technical assistance.
Turn the power source off and on. Replace
the battery on the panel board and contact
technical assistance if the error persists.
3301291-EN
3301291