Meter setup to measure voltage:
•
Set the rotary switch to the voltage ( or m ) setting. (The m setting is only for DC millivolt
measurements.)
•
Press the "DC/AC" button to select AC or DC voltage measurement, the display will show the corresponding
symbol.
•
Insert the black lead in the "COM" jack.
•
Insert the red lead in the "
Connect:
Back probe to the negative (-) circuit or to ground.
Red probe to the circuit coming from the power source.
Resistance Measurements
Resistance is a static measurement which means that it must be measured with the power off. It is measured in
Ohms (Ω) and the values can vary greatly from a few milliohms (mΩ) for contact resistance to billions of ohms
for insulators.
TURN OFF POWER AND DISCHARGE ALL CAPACITORS IN THE CIRCUIT TO BE TESTED BEFORE MAKING
IN-CIRCUIT RESISTANCE MEASUREMENTS. ACCURATE MEASUREMENT IS NOT POSSIBLE IF EXTERNAL
NOTE:
The resistance in the test probes can affect accuracy in the 400 range. Short the probes together and
press the "REL" button to subtract test lead resistance from the measurement.
18
All manuals and user guides at all-guides.com
Black
12V Battery
Parallel Connection
" jack.
WARNING
OR RESIDUAL VOLTAGE IS PRESENT.
Red
MACTOOLS.COM