Descargar Imprimir esta página

MAC TOOLS EM721 Manual Del Usuario página 72

Publicidad

Idiomas disponibles

Idiomas disponibles

Diode Test
Range
2.000V
Continuity Test
The buzzer will sound when the resistance is less than about 40Ω.
The buzzer will not sound when the resistance is more than 150Ω.
The buzzer may or may not sound when the resistance is between
40Ω and 150Ω.
Capacitance
Range
1µF
10µF
100µF
1,000µF
Note:
Accuracy is for capacitors that have negligible dielectric absorption.
Temperature
Range
-40°C to 0°C
0°C to 400°C
-40°F to 0°F
0°F to 400°F
400°F to 2,498°F
Use K type thermocouple.
Note:
1.
Accuracy does not include error of the thermocouple probe.
2.
Accuracy specification assumes ambient temperature is stable to ±1°C. For ambient temperature changes
of ±5°C, rated accuracy applies after 1 hour.
72
All manuals and user guides at all-guides.com
Description
The approximate forward
voltage drop of the diode is
shown on the display.
Description
Resolution
0.001µF
0.01µF
0.1µF
1µF
Resolution
0.1°C
0.1°C
1°C
0.1°F
0.1°F
1°F
Remark
Open Circuit Voltage: about 3V dc
Test Current: about 0.24mA
Remark
Open Circuit Voltage:
about 3V dc
Accuracy
± (2.0% + 5)
± (3.0% + 5)
± (5.0% + 5)
Accuracy
± (4.0°C + 3 digits)
± (2% + 3°C)
± 3.0% of reading
± (7.2°F + 3 digits)
± (2% + 5.4°F)
± 3.0% of reading
MACTOOLS.COM