9.
Wheel balancing
WARNING – Incorrectly balanced wheels
Risk of injury due to change in handling
characteristics of vehicle.
SBM V85 A must be positioned on a flat
surface and must be firmly bolted to the
floor.
Specified flange must be mounted on
clean and grease-free shaft.
Use the specified accessories (cone,
spacer rings).
Rim must contact flange accurately,
remove any dirt.
Perform a check measurement after
applying balancing weights.
1. Switch on the SBM V85 A at the on/off switch.
 The "Start page" is opened.
2. Open the "wheel balancing main page" with < I >.
9.1
Selection of vehicle type and
balancing program
i
Static balancing is recommended for wheels with
a width of less than 3.5": In this case only the rim
diameter value is entered. The values for distance
and width of the rim can be set arbitrarily in inches
or mm.
1. Check the currently selected type of vehicle
(passenger car or motorcycle) in the status bar, alter
if necessary and confirm with < I >.
2. Check the currently selected balancing program in the
status bar, alter if necessary and confirm with < I >.
SICAM srl soc. Unip
xxx
Wheel balancing | SBM V85 A | 47
Static balancing on plane 3
Static balancing on plane 2
Static balancing on plane 1
Pax2: Pax rim for concealed adhesive weights
Pax1: Pax rim with adhesive weights
Alu5: Adhesive weights on inside /
clip-on weights on outside
Alu4: Clip-on weights on inside /
adhesive weights on outside*
Alu3: Clip-on weights on inside /
concealed adhesive weights on outside
Alu2: Concealed adhesive weights
Alu1: Standard program for adhesive weights*
Standard program for clip-on weights
*
The weight must be raised slightly if the adhesive weight can-
not be attached in the vicinity of the outer edge of the rim (rim
flange) on account of the design of the rim.
9.2
Entering rim data
i
If electronic wheel data recording is not possible,
the wheel data can also be entered manually.
i
The electronic gauge arm is not required for the
balancing programs Alu2, Alu3 and Pax2 (ALUDATA®).
Both measurement locations are recorded with the
vernier caliper.
1. Apply the electronic vernier caliper for rim distance
and rim diameter to the rim.
 The measurement location is indicated on the
651012-12_Sr
monitor in accordance with the balancing pro-
gram selected.
 Storage of the position is confirmed by an acous-
tic signal and the position data are displayed.