12.3.3
Calibration of electronic vernier caliper
i
Follow the instructions shown on the monitor.
Calibration of the electronic slide calliper/ angular
width gauge without external gauge
1. Select calibration of the slide calliper and the
angular width gauge and confirm using < I >.
2. Move the distance cursor to standby position and
press < I >.
3. Move the distance reading cursor to 0 mm. Set the
value read and press < I >.
4. Move the distance reading cursor to 200 mm. Set
the value read and press < I >.
5. Assemble a 14'' or 15'' steel sample wheel. Set the
value read and press < I >.
6. Set the wheel measurements and, with the distance
reading cursor resting on the wheel itself, press < I >.
"
Procedure completed.
SICAM srl soc. Unip
Maintenance | SBM V85 A | 55
xxx
12.3.4
Calibration of SBM V85 A
i
Follow the instructions shown on the monitor.
1. Attach a motor vehicle wheel of medium size
(e.g. width 5.5", diameter 14") and in very good
condition to the flange.
2. Select SBM V85 A calibration and confirm with < I >.
 Calibration is started.
3. Enter the rim data and confirm with < I >.
4. Press < I >.
 Measurement commences.
5. Enter any balance weight between 40 g and 120 g
and confirm with < I >.
6. Attach a balance weight of the value entered to the
inner side of the wheel.
7. Press < I >.
 Measurement commences.
8. Turn the wheel until the balance weight is in the
12 o'clock position.
9. Remove the balance weight from the inner side
of the wheel and attach it to the outer side
(12 o'clock).
10. Press < I >.
 Measurement commences.
11. Turn the wheel such that the weight is in the 6
o'clock position.
12. Press < I >.
"
This completes calibration.
i
The calibration made is permanently stored
automatically.